  1. R

    Garage Door Problem

    I think the problem here is fairly apparent. Can anyone identify the hardware I have or suggest the easiest way to fix ? Many thanks in advance
  2. R

    Honeywell 3 port valve question

    Glowworm Ultimate 120ff see this thread - //www.diynot.com/forums/plumbing/glow-worm-ultimate-120ff.384747/
  3. R

    Honeywell 3 port valve question

    Also, I'm now fairly sure the rattling noise is the pump. Grundfoss 15/60. If you shake the pipe when it's off you can definitely here something rattling around inside . I assume this means it's on the way out, it's also noisier than it used to be when in operation.
  4. R

    Honeywell 3 port valve question

    Did some further checks :- Mid position is working If CH is satisfied, valves stays in CH position If HW satisfied , valve stays in HW position. I assume this is normal ? Only problem is when HW satisfied my pump overrun goes on for ages as the water though the boiler is just...
  5. R

    Honeywell 3 port valve question

    V4073A1088 28MM HONEYWELL MOTORISED MID-POSITION VALVE At rest with no demand from heating or HW, the motor is very hot. Is this normal ? Am also fairly sure the mid-positon for CH/HW demand is not working. Also, I am sure the valve is rattling inside the pipework. Have tried adjusting the...
  6. R

    Glow-worm Ultimate 120FF

    Changed the stat, overrun now working more often
  7. R

    Glow-worm Ultimate 120FF

    5 connections to stat
  8. R

    Glow-worm Ultimate 120FF

    They said assuming wiring correct pump won't overrun unless boiler stat senses >70c in Max temp on this model is about 82c with stat on max, not sure on min ? Maybe stat needs replacing, although it seems to work OK for normal boiler operation
  9. R

    Glow-worm Ultimate 120FF

    yes pump is wired to boiler, online glowworm manual (2004) describes a normal pump-overrun The 1998 manual I have says overrun will work when boiler stat set to max. However, it doesn't , but only comes on as previously described. I wonder if Glowworm tech support can confirm how it's...
  10. R

    Glow-worm Ultimate 120FF

    No I dont think it ever has. Just occasionally comes on when I suspect it detects boiler is too hot. Definitely two types of pcb - see http://www.plumbtraders.co.uk/product/glow-worm-s900817-pcb-alternative-kfb-see-rems/#.UpSeYMTIak4
  11. R

    Glow-worm Ultimate 120FF

    I have a Glow-worm Ultimate 120FF 1998, one fuse PCB I do not seem to have a "normal" pump overrun, ie when controls stop calling for heat the boiler/pumop switch off. This can result in heat building up inside the boiler and lots of gurgling etc. Very seldomly, the pump will come back on...
  12. R

    No tension in my velux blind!

    same problem, any tips ??
  13. R

    Glowworm Ultimate - descale heat exchanger ?

    Now ready for my DS40 treatment. I think I would like to isolate the boiler as far as possible, is this a case of closing the TRV's and lockshields on most of the rads ? Also what is the best length of time to circulate for, instructions are a bit vague.
  14. R

    Glowworm Ultimate - descale heat exchanger ?

    Have a Glowworm Ultimate 120ff, heat exchanger is fizzing and gurgling and kettleing Can I add treatment to the system to cure ? or do I need a powerflush ? I have drained down the system and added inhibitor in the past etc so know how to do it. If I can do it manually which chemicals...