  1. A

    Low Pitch Roof Preparation

    I'm now seeing a bigger issue as a result of my car port roof structure. The counter battens and horizontal battens have been screwed down at the same place in the joists that run through the rafters because there are only 4 rafters across the 6m building which are on the structure posts. It...
  2. Roof

    Roof

    Roof
  3. A

    Low Pitch Roof Preparation

    This is a timber framed enclosed garage and the roof is overboard with T&G boards. In preparation for metal sheets I have fitted a breather membrane directly to the boards and counter battened at 600 centres to provide good ventilation for likely condensation. I feel I have missed a couple of...
  4. A

    Loose Half Newel Post

    Thanks for your help. This job sounds like it's best left to a professional.
  5. A

    Loose Half Newel Post

    not sure if a noggin has been put in the wall. What size opening do you mean on the other side of the wall as i don't want to create more repair work than necessary.
  6. A

    Loose Half Newel Post

    It's a hollow partitioned wall
  7. A

    Loose Half Newel Post

    I have just moved into our new home and discovered the handrail on our walkway is loose. On investigation the timber fitted to the wall which the hand rail fixes into has movement, and as you can see from the pictures their is a gap at the bottom. From research i understand this is called a half...
  8. A

    New Socket off a Switched FCU?

    Yes, I could well have researched this but using the forum has enlightened me and generated excellent advice and help, which may benefit others in the future. Not sure why it is concerning. Where did you get the 3A feed from? 13 amp fuse is fitted which until i research, I can only presume...
  9. A

    New Socket off a Switched FCU?

    Good suggestion and something i can check tomorrow. I moved into this property a few weeks ago so still checking out what I have invested my hard earned cash into!
  10. A

    New Socket off a Switched FCU?

    When i was in the trade 5 x running current was the rule of thumb for motor start up current . Thanks for the heads up, hopefully there will be no issues with voltage drop but i think I will be ok.
  11. A

    New Socket off a Switched FCU?

    Thanks John The ring circuit is RCD protected. Should i consider doing this another way? I was 16th edition qualified 13 years ago but my career has gone in a very different direction so i'm not afraid to admit i'm no expert, but certainly know how to do a job correctly. Any ideas...
  12. A

    New Socket off a Switched FCU?

    I need to add a single mains socket in a room for TV/SKY and the only power source in the room is a switched FCU which is a spur of the ring main. The switched FCU is for a macerator pump but the FCU is installed outside the bathroom. I would like to run surface mounted/1.5mm flex...
  13. A

    Custom Bath Panel help

    something to think about...
  14. A

    Custom Bath Panel help

    thanks foxhole If i do this do you think a 200mm plinth will look ok?
  15. A

    Custom Bath Panel help

    Good evening I have recently installed a fantastic whirlpool bath in my home but i'm finding it difficult to find a gloss white bath panel for it. The measurements required are 1700 x 650 (yes i have heard the "you need a ladder to get in there" jokes already!! :) ) I have found a...
  16. A

    two circuits on single RCBO?

    Just spoke to Warmup customer services which was a waste of time. They can't advise if a 16 amp RCBO needs fusing down for the 5.2 Amp UFH. Apparantly its up to the electrician to decide?
  17. A

    two circuits on single RCBO?

    Thanks for the advice. The UFH is Warmup and is suitable for bathroom instalations. I will contact warmup and ask if a FCU is needed for isolation. The UFH load is 5 amps so wouldn't it be compolsoary to downrate the supply to 13 amps? I'm aware of the Part P regs but haven't decided if i...
  18. A

    two circuits on single RCBO?

    I would appreciate some guidance for installing UFH and a whirlpool bath in my bathroom on a 16A rcbo currently unused in my CU. UFH is rated @ 5 amps Whirlpool bath @ 4 amps Can i install two seperate loads on a single RCBO? The UFH is controlled/switched by an electronic programmer...
  19. A

    Whirlpool Bath Wiring

    Can i run the cable un-fixed between the JB and conduit (distance approx 1m)? Other than clipping it to the floor, i can't think of any other methods.
  20. A

    Whirlpool Bath Wiring

    Thanks for the information. In picture 1 the bath will be positioned on the chipboard on the left hand side of the picture. The junction box on the bath sits just behind the bath panel, about 1m away from where i plan to end the conduit.