  1. T

    New Flat Roof - Replacing Concrete Roof

    Any ideas how these concreate roof a likely to be formed, as in poured to make one big slab or are they slotted slabs? Just wanted to know what tools would be required to remove this? Thanks
  2. T

    New Flat Roof - Replacing Concrete Roof

    Concreate has cracked and is leaking so i thought its best to get rid of this and go in with a cold deck and have it insulated. Okay so i would need to lift the white facia and tack a lead flashing there?
  3. T

    New Flat Roof - Replacing Concrete Roof

    Hi, Planning on removing an old concreate flat roof and will be replacing it with a timber joist cold deck. Wanted some advice how to finish this off on the neighbors side as they have pitched roof and the side has just been cladded. Any suggestions would be appreciated Thanks
  4. T

    DIY Shed

    Yes was thinking of painting it first and see if its possible to make a water tight using some kind of sealer, but if its not going ot last more that 10 years then i guess it best using something else.
  5. T

    DIY Shed

    Hello guys, I'm planning on making a shed using 4x2 timber and look at options as to what to cover this with. Shiplap cladding is quite pricey so was looking at OSB3 sheets, not sure if there is a good way to fully water proof this? Any thoughts on this or other recommendations ? Thanks!
  6. T

    Junction box intermittently shorting (possibly)

    If its a component issues can it be intermittent? also would it take out all controls... the only 2 things I have going on/off is hot water and heating... in the morning there is an overlap between the two.
  7. T

    Junction box intermittently shorting (possibly)

    Yep i've got one.. only ever used it for basic continuity. you could be correct about the neutral.. after several on/off its back... Sorry what you you mean about the neon bit? maybe when its drawing current something is going on...
  8. T

    Junction box intermittently shorting (possibly)

    Just tested live to the junction box n boiler using a tester screwdriver which was live... Strange that it happens in the mornings... If the over heat stat in a unvented was to kick in would it trip out everything? Shouldn't do unless it's wired incorrectly? Thanks
  9. T

    Junction box intermittently shorting (possibly)

    Hey guys, Today everything just cut off and I'm not getting any power to the boiler heatmiser UH8 or any of the neo stats...I've tested that I've got live coming into the junction box... can't seem to get it going anymore... Any suggestions on what I can test...
  10. T

    Junction box intermittently shorting (possibly)

    I've currently got a 10way honeywell... its being shorted somewhere (I think) but strangely it's not consistently and struggling to find out what's causing it... everything connected to the junction box would die..the CU is RCD protected but doesn't trip.. switching off the fuse spur on/of makes...
  11. T

    Operating GAS pressure at the appliance

    This forum does not support DIY gas work.
  12. T

    What type of isolator value do I need please

    Any of these will do- https://www.screwfix.com/p/flexible-tap-connector-with-valve-15mm-x-1-2-x-300mm/3558g https://www.screwfix.com/p/full-bore-isolating-valve-15mm/46860
  13. T

    Bathroom Extractor Fan

    Yes the lights/fan are on a 6amp mcb just that it's hasn't got a isolation switch. Would this be okay to add https://www.screwfix.com/p/lap-10ax-1-gang-3-pole-fan-isolator-switch-white/26196
  14. T

    Bathroom Extractor Fan

    Hi guys, I'm in the process of replacing a bathroom shower fan with a powerful one which is mains powered 230v IPX4. Currently it's wired to its own switch so it doesn't come on with the lights which is the way I would like to keep it. The new fan mention the below. The CU is RCD already so...
  15. T

    DIY Texecom Premier Elite 48

    I was thinking of that but it will be very tricky as I have a solid ground floor inside. I guess it will need to be bury in trunking quite deep once its out in the garden to the out house too..
  16. T

    DIY Texecom Premier Elite 48

    For the main house I have a texecom premier elite all hard wired. I'm thinking of putting a separate alarm for the out-building but would like to be able to arm/disarm this from the house it self. ideally with a prox tag too.. Any recommendations what product would best suit for this?
  17. T

    DIY Texecom Premier Elite 48

    Hi guys, I'm thinking of buying a Texecom ricochet kit 0001 for that garage, I would like a wireless RKP in the house so I can arm and disarm the outhouse garage and also have a hard wire RKP in the garage itself. My question is I have a spare premier elite RKP and wanted to know if this can be...
  18. T

    Warm deck Roof

    Thanks for the reply. Would it be okay to put insulation plasterboard from inside and be done with it? Thanks
  19. T

    Warm deck Roof

    So from the bottom up you see the joists then ferrerings, then 18mm plywood, then 100mm insulation, then 18mm OSB board which has EPDM rubber on it. I can't see any vapor barrier and the plastered board is standard as in not foiled back....
  20. T

    Warm deck Roof

    Hi, I've got a warm deck roof which which was a garage conversion 20 years ago... ever since the bedroom has always been freezing cold and I cannot seem to figure out the root cause. The outer walls all have 100min insulation cavity walls aswell as external wall insulation which is 50mm so I've...