Search results

  1. M

    CK 700L alarm panel or board.

    Your right i had connected the speaker to the bell terminals !! I have now connected a spare speaker to the speaker terminals using the engineer (6) options, tested the internal speaker which worked fine. I will now search for a replacement internal speaker. Basing the external siren on...
  2. M

    CK 700L alarm panel or board.

    ok, so if i was to use my meter at each + and - for the bell and internal siren what voltage should i have?
  3. M

    CK 700L alarm panel or board.

    Using a meter at both connections inside the alarm box (siren and internal speaker) what would you expect to see? Regards
  4. M

    CK 700L alarm panel or board.

    Hi Sparky Ive just fitted the spare speaker to the siren output on the alarm board, some popping was heard then it stopped, i removed it to find that the speaker is now open circuit? That speaker has now blown? WTF is going on... Now i am confused.
  5. M

    CK 700L alarm panel or board.

    Hi, I have carried out the checks that you advised on both speakers both of which were open circuit? Could this be a coincidence that both seem to have failed? I checked a spare speaker that i had in my garage with a 10.5 ohmn meter reading ( as you advised ). The system is engineering...
  6. M

    CK 700L alarm panel or board.

    When arming the system prior to leaving the house or entering the house the internal buzzer is almost silent? (previously it was much louder) There are no lights on the keypad apart from mains and day which is correct. I tried triggering the system but i have no internal sounder or external...
  7. M

    CK 700L alarm panel or board.

    I was advised the same (see my previous posts) so i found a company that supplies a new panel and key pad, i replaced both and still have the same issues, i cant afford to replace the complete alarm system and have already paid a sparky to look at it, his advice was incorrect. BTW why were...
  8. M

    Help Needed Securit 800L Alarm system

    I have tried the bell test from the key pad and no it doesnt sound? nor does the internal siren? when you say manually, do you mean from the inside the panel? The problem i have with checking the wiring is, the alarm system was installed when the house was built and so no visible cables...
  9. M

    Help Needed Securit 800L Alarm system

    Hi Guys, Following on from my previous conversation... Just an update and again looking to pick your brains, i have now replaced the alarm box complete and the key pad, using the existing wiring which was installed when the house / alarm was fitted/ built, again the system seems to be...
  10. M

    Help Needed Securit 800L Alarm system

    I have tested the battery 13.9v dc = ok I have tested all the fuses = ok Over the weekend i powered down the whole system, at no point did the external siren sound nor did the internal bell, just a very low pitched noise? All the lights on the keypad show TPR and zone trigger when...
  11. M

    Help Needed Securit 800L Alarm system

    Thanks for your replies alarm, very much appreciated. I will check the battery with a meter and take it from there. Do you know if a new board is available or is a new alarm box?
  12. M

    Help Needed Securit 800L Alarm system

    Thanks for reply, i have the user manual and the installation manual and have followed there very minor trouble shooting guide. I am not a alarm fitter but an auto electrician and so understand all the info. I was thinking along the same lines as a possible PCB issue, but would prefer...
  13. M

    Help Needed Securit 800L Alarm system

    Hi Guys, This week something strange has happened to our house alarm, until this happened the system has been functioning absolutely fine. When entering the house, a loud tone was heard until the input of the code, now when you enter, the loud tone noise has almost disappeared to a very...
  14. M

    Securit 800L Problem

    Nothing lights up? No lights on any of the sensors or remote panel, the only thing that is on is the internal siren which i disconnected inside the alarm box.
  15. M

    Securit 800L Problem

    Thanks for your reply, ive removed that glass fuse and it looks fine, i dont have a multimeter at home which makes things so much harder. Sort circuit? I cant see how that would be possible as the sensor is a metre away from the control box, 6 wires, + - and two tamper wires and signal...
  16. M

    Securit 800L Problem

    Help Please, Today i have added an additional PIR sensor to my securit 800L alarm system, the problem became apparent when after i had fitted the sensor i follwed the boot up process, but now i have no control panel lights and the internal siren is sounding. I have now removed the...
Back