    Old Central heating system not circulating properly

    The old pump was set at 3 and so I've set the new one to the same. Today all the radiators are equally 'warm' at about 31C which is pretty poor. Tony, Yes I believe one benefit of using 8mm instead of 15mm is for Reduced heat loss, which is exactly the opposite of what I thought I was...
  2. D

    Old Central heating system not circulating properly

    Lol!! :lol: Yes you're right about the rambling! I just wanted to get as much info in there as poss to give a good picture of what it is and what's already been done...I may have overdone it a little :) I know it could take 4 weeks before I'll know if the X400 actually does anything, but...
  3. D

    Old Central heating system not circulating properly

    Hi, I've been repairing my heating after some frozen pipes and can't seem to get it to circulate properly. It's an old Baxi back boiler that provides hot water and runs 7 radiators (open system, 8mm copper pipe from just after boiler), There was a burst in the pipes feeding the boiler and the...
  4. D

    Dryer on spur trips RCD

    Spot on. Just checked the plug on the extension lead.... Earth had fallen out, L and N had never been tightened!! :shock: I'll think twice before borrowing electrical equipment from a neighbour in future!! Glad I took the precaution of not touching the thing when it was on the extension...
  5. D

    Dryer on spur trips RCD

    Ok, I checked the heater and it had water in it, probably from the move. I dryed it out with a hot air gun and now it works. Which only leaves the question... Why did it work off the extension without tripping???
  6. D

    Dryer on spur trips RCD

    No, it trips just as its about to start, and its a condensing dryer so there's no vent. I just replaced the cable and theres no change. I have seen a similar post about a condenser dryer with a short in the heater, but then if that was the case here, why does mine work off an extension lead...
  7. D

    Dryer on spur trips RCD

    Thanks Chris, Yes the neutral is on the correct bar. I'll replace the cable and try again. Cheers.
  8. D

    Dryer on spur trips RCD

    On moving to a new(old) house, I added a short (2M) spur to the ring main in order to put my dryer in the cellar. New cable, new socket, wired directly into the ring main MCB of my split CU (Memera 200AD). The dryer display powers up but trips the RCD when a drying cycle is started. I ran an...