Search results

  1. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Cheques in the post addressed to; Kevplumb America hope it gets there :) Yeah looks like I didn't need the servo, nevermind. Can't blame the engineer too much, seems the servos do go wrong on this model. Thanks again :)
  2. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Its come apart now and the diaphragm is split :) Thanks for your help Kev, you are a superstar :)
  3. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Whoops, I see what you mean now :) The huge pin that pushes the actuator :oops: :oops: :oops: I just assumed that it was turned by pressure :oops: I have the water section off just one bolt that holds the casing together is proving a bit troublesome to remove, just sprayed some...
  4. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Hi Kev, thanks for your info so far, its much appreciated you taking the time to help. I was just adding another symptom, you used to be able to manually turn the actuator which gave you hot water, now the boiler is fireing but no hot water is coming out. The servo that operates the...
  5. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Think there might be a new problem here. I have just forced the servo open to run a bath and the hot water is just luke warm????
  6. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Thanks Kev, I am happy to give that a go. Just out of interest do you know how a problem with the water section would affect the servo; I take it pressure from the water section makes its way to the servo somehow?
  7. P

    Vaillant VCW GB 242 EH Central Heating no Hot Water

    Hi, I am having trouble with my Vaillant VCW GB 242 EH the Central Heating is working fine but there is no hot water. There is a servo on it, which turns around and activates a micro switch to tell the boiler that water is flowing. The servo isn't turning around far enough to activate the...