  1. H

    Central Heating Stopped working??

    All sorted, it was the capacitor. Thanks for all the advice and help guys
  2. H

    Central Heating Stopped working??

    I removed the electrodes to clean the nozzle hence them not looking right. I've reset the gap also since then. I don't do electrics so am a bit stuck on that side !
  3. H

    Central Heating Stopped working??

    [/IMG] Have taken everything apart again. Have checked the fuel pump and it turns freely, have cleaned the photocell? I'm not sure that it is the pump as the motor doesn't appear to turn over either, see this vid
  4. H

    Central Heating Stopped working??

    No fan not running It's a Grant Euroflame 70/90 http://www.grantuk.com/userfiles/download_29.pdf
  5. H

    Central Heating Stopped working??

    Nozzle is wet, have cleaned the electrodes and checked the gap, cleaned the pump filter and yes the CH circ pump is turning. Have just tried again and it clicks, makes a constant humming noise, then makes another noise, then trips out, meanwhile the pipes are banging for about 15 seconds??
  6. H

    Central Heating Stopped working??

    The heating came on yesterday and went off as normal after 2 hours, so I went to put it back on as it was cold but it wouldn't fire up. I therefore went round the house and bled all the rads as the pipes had been banging recently and got some air out, plus this also made the pipes bang a bit...