Search results

  1. B

    Touch Dimmer

    Hi guys. I have bought a push button dimmer switch and it has 3 connections, Live, load and master. The wiring were this is going has a live, switched live and earth. I have wired the live to live and switched live to load but the light will not operate with push button, I have even reversed...
  2. B

    Labgear HDU681S Wiring

    I think you have just blown it. Basically I am just after sky in main room with the option to watch it upstairs in bed. Probably will never have both on at same time. Maybe 1 with freeview and one with sky.
  3. B

    Labgear HDU681S Wiring

    Hi thanks for that. That now makes sense. I have only just got the DA and it can go back, with regards to satellite feeds they have not been done either. I have just installed a new sat dish with quad LNB wires have not been run yet. I am open to ideas of how to distribute satellite signals...
  4. B

    Labgear HDU681S Wiring

    I am just asking the best way to wire a hdu681s so it works all around the house. Do I connect 2 wires from LNB to distribution board, then 3 wires to sky tv box, one of those wires used as a return. Thanks
  5. B

    Labgear HDU681S Wiring

    Hi I have bought a Labgear HDU681S to distribute sky around the house. I have read various forums on the wiring if anyone can help. I have fitted a new sky dish and was going to run 2 cables from the LNB to the Labgear distribution board, one for Sky and one for Sky+. From here I was...
  6. B

    Wiring help

    Riveralt Wonderful thanks very much.
  7. B

    Wiring help

    Hi. I can easily get back to the fuse box. Would it be ok to run a new wire from lighting circuit to switch.
  8. B

    Wiring help

    It won't be possible to take a feed from light fitting as all plastered in now. I have 2 wires at switch now that feed a 12 volt led transformer to plinth lights. I also as you say have a 2 wires that are switching the live for the kitchen downlights. I have brown and blue feeding...
  9. B

    Wiring help

    Thanks for quick replies, can I take a neutral from another switch. Is there anyway I can make this work.
  10. B

    Wiring help

    Hi wonder if anyone can help. I have downlights in kitchen with power going back to double switch. 1 live wire, I neutral and 1 earth. This circuit works fine with live in L1 and neutral to L2. I have now installed plinth lights and have another single wire going back to double switch but...
  11. B

    Veritas excel keypad help

    Hi can anyone help I have a veritas excel system fitted with 2x LCD keypads all worked fine for around 2 months now one keypad won't work correctly. It seems that all the bottom row yes, no 0, no, chime and reset all give the dull noise, the noise when you key something in wrong all lights are...
  12. B

    Accenta g3 new zone without bell box ringing

    Hi can anyone help I am about to install a door sensor on a accenta g3 in my conservatory, when I remove the power and battery back up to the control panel I know the external bell box will go off, is there a way to stop the bell box from going off while I add this new zone. Thanks
  13. B

    Thermostatic shower runs hot and cold

    Hi I wonder if anyone can help, I have a 2 month old main combi boiler 30kw and I have had installed a new atmos Qube thermostatic shower, the problem is the flow rate at the shower is not great and the shower runs ok for a few minutes then runs cold, then goes ok and so on, I have the boiler...
  14. B

    Texecom speech dialler

    Hi can you tell me if you think this is ok , I have 1x 6 core cable from panel to speech dialler I have 1 to 12v, 1 to 0v, 1 back to earth, 2 x tamper and 1 for the intruder output 3, if I now invert the outputs in particular page 35 of the manual and change communicator outputs option 3 to high...
  15. B

    Texecom speech dialler

    Hi thanks for your reply, can you tell me if this is done on the speech dialler or on the actual alarm panel
  16. B

    Texecom speech dialler

    Hi can anyone help, I have a Texecom excel alarm and a Texecom speech dialler, when the alarm goes off it will only dial or text my mobile once the reset button is pressed on the keypad to the alarm it won't dial when the alarm goes off as soon as I hit reset it dials and texts. I only have...
  17. B

    Texecom Speech and Text Dialler to Veritas Excel

    Hi can you tell me how the BB filter fits and were i can buy one from, once again thanks for your help.
  18. B

    Texecom Speech and Text Dialler to Veritas Excel

    Hi can anyone help, i have just purchased a texecom speech and text dialler and am looking to wire it to my veritas excel alarm, please can anyone give me the wiring for this, also what wires from the phone line to the speech dialler to.
  19. B

    Veritas Excel Help

    Hi alarm, i installed an odyseey 4E, can you please explain what i got to do, many thanks for your reply
  20. B

    Veritas Excel Help

    I have installed a veritas excel alarm 2 keypads, 4 door sensors and 4 PIR detectors, and a odyssey bell box everything is working fine but when i moved a couple of PIRS, i powered down the system and removed the battery back up. I thought at that point the bell box should sound until either...
Back
Top