  1. P

    Resoldering a leaking soldered joint ??

    Usually a trace of nearby residual water in the pipe . If the joint holds leak-free for some hours it's unlikely to leak later.
  2. P

    ABS pipe burried in concrete wall with water line behind. How to add a fitting?

    Makes no sense to me. OK, codes and practices differ, but encasing pipework in vertical sheets or piers of concrete seems mad IMO . What about thermal expansion of the pipework- not inconsiderable for ABS ? I think you'd be better off consulting a more local forum. Best wishes.
  3. P

    High/ low modules silicone

    Leaving aside the mould issue..
  4. P

    Advice needed

    Its got to be the valve, the tube, or the push button (bellows). Always worth checking the tube for splits/loose ends. The valve in the link looks identical to me. If so it will twist off the cradle so would require no further dismantling to swap.
  5. P

    Balanced Flue Gas Fire Question

    Drying plaster will make the room feel cooler.
  6. P

    Rodetal boss thingy

    Ebay
  7. P

    Balanced Flue Gas Fire Question

    Gas is being burnt @ 8 or 9 kW where's that heat going? Radiant to the room, convective within the plasterboarded cavity with some convection/radiation eventually to the room as things warm up and lastly chimney losses. I'd be hard put to it to measure and disentangle these three.
  8. P

    What type of shower cartridge is this and how to remove?

    +1 for the recommendation for showerdoc.com
  9. P

    Mothballing a bathroom

    Clingfilm the bog to retain the trap seal. Do remember to remove on first re-use!
  10. P

    ABS pipe burried in concrete wall with water line behind. How to add a fitting?

    This is a UK site; practices and material ranges differ from yours That said, try exposing more pipe and using what I believe you colonials term a "no-hub" fitting in the appropriate size as a slip connector...
  11. P

    Inspection chamber benching

    3:1 sand : cement (some would even go 1:1) , you lean in and contour/shape/polish it as it goes off. Waterproofing/accelerant additives as you like.
  12. P

    Little Plumber Electronic Descalee

    Oh, but they come up with most creative mumbo-jumbo about "how they work" [i.e. presupposing that do] but are (ahem) more reticent on the subject of independent trials evidencing that they do anything but sweet FA.
  13. P

    Replacing small electric water heater

    Nah, follow the manufacturers' instructions and you'll be fine.
  14. P

    Replacing small electric water heater

    Unvented vessels of up to 15litre capacity are exempted in the regs. I'd recommend, if you're going for the Ariston 10l on mains water supply, to fit the full safety kit including expansion vessel.
  15. P

    Leaking joint near water meter

    You don't own that meter so not your problem. The leaks you higlight are all part of the meter installation. Call your local water undertaking or whoever you pay your water bills to and tell them there's a leak at the (internally located!) meter.
  16. P

    Manual/hand crank water pump to prime shower pump?

    You don't need to prime your pump.* You do need to ensure that your pump position and pipework layout are exactly in accordance with the pump manufacturers written instructions,where you'll find several acceptable alternatives. * other than running the shower both hot and cold with the power...
  17. P

    When is a gas oven a Commercial Appliance and thus a Kitchen a Commercial Kitchen?

    It's a grey area. For example a small B&B serving half a dozen cooked breakfasts on a domestic cooker would not be regarded as commercial for gas safety purposes although "commercial" in the sense of money changing hands. Do please ask Gas Safe for a ruling: I'd be interested in their response.
  18. P

    Do anti-scale devices ACTUALLY work?

    ^^^ My view exactly.
  19. P

    Mixer tap cartridge disintegrated during removal

    Small needle-nose pliers or dental hook.
  20. P

    Clicking stack

    Soil pipe suspended from clip with a cm or so above full insertion from socket end below or resting on lower socketed end?