    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Oh dear, well that explains just about everything, i was expecting a 26kw to do better as it is twice the size of the oil boiler it replaced, running it off the dial don`t seem right for a german bit of kit/quality that we are used to, the dial now is off the clock between 6 and Serv but you...
  2. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi thanks guys, this is a very good idea "mysteryman" it makes the best sense where to send the overrun letent heat. However, my plumber has checked the system and he assures me that No hot water is going past the bypass valve if either of the motorised valves are open, so no hot water is...
  3. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Do they! I think the best wey out for me is to get the existing bypass to go via a longer rute then back to the boiler so that the ruturn water is less hot, the hot water that i believe is shorting back to the boiler causing it to shut down. Cheers
  4. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Thanks, but i`ll stick with the Viessmann, not looking for another boiler just yet, i know i have had two full months from it and the rumour is condensers don`t last long, and i`ll be well pushed to get it to last as long as the old oil Worcester (21 years) that it replaced but if i am kind to...
  5. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    I could have thrown away the viessmann timer, fitted the original back or a `boggo`one on the wall and lernt nothing. This was a very tidy mod using quality parts that will no doubt last longer than a `boggo`one and my plumber commented it all looks very trick and tidy not a wire or any of his...
  6. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    I understand. But the reason i am proposing a bypass shutoff valve is to let the hot water flow around the bypass loop during `pump overrun` only. The rooms don`t get hot enough for the TRV`s to operate now yet alone when the weather does get cold and the room stat in the living room is...
  7. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Could i fit an electriclly operated shutoff valve in place of the bypass? Why?
  8. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi all, sorry for the very late reply. You may remember that i had problems fitting the 2x channel digital timer to my 26kw open vent Viessmann Compak WB1B as i could not find the switched timed outputs! After contacting Viessmann for a second time and talking to another engineer he told me...
  9. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi, sorry for the late reply, i have been away. I have to confess, when i said the original was an `S` plan it was a kind of hi-bred plan! The oil boiler that had been running for 20+ years was installed by an old school plumber, HW gravity and the CH pumped. (four pipes to the boiler...
  10. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    The pump Will be connected to the boiler whatever it takes in cable and time, this i assume will give the pump over run but a three port valve always has a path open for the over run hot water to pump to, zone valves close both the paths on a `S` plan and require a return loop with a bypass valve?
  11. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    I have contacted Viessmann and they say i need to fit their cylinder demand box for the 2 channel timer to operate correctly, i am still not sure this will give me what i want, and i may install the old programmer. Regarding the pump over run on this boiler what would be the best solution...
  12. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Thanks guys, i assumed by fitting the viessmann timer it would give me the 2 timed outputs, however i will ring viessmann and talk to technical and post back with the answer. Sorry about starting a second thread only i could not find how to answer. Thanks very much all.
  13. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi yes it is the 26kw Compak Viessmann Number WB1B 319 I now know it requires 240v input on 1 to fire the boiler, the circuit shows 3 options of room stat on page 42, i now just need to know where to pick up the timed out puts for CH and HW. Thanks
  14. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Thanks Matt, but on this model the clock plugs into x7, i now know that the ruturn 240v goes to 1 from the zone valve end switches to make the boiler run, but which are the "timed" 240v out signals that go to the room stat and the cyl stat? Cheers, kelly
  15. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi thanks eveyone, it is a Viessmann digital 2 channel timer viessmann number 7296 063 it fits to the boiler and it plugs into x7 of the pcb, simple, i got this thinking it would make the wiring "easy" and it is the correct programmer for this boiler, i did Not opt for the weather compensation...
  16. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi, I have purchased a new Viessmann 100-W WB1B 26kw open vent gas condensing boiler , viessmann reccommend it ideal for `y` and `S` plan systems and i want to connect it to my existing `S` plan system using cylinder and room stats with Honywell zone valves. I have also brought the digital...
  17. K

    Viessmann 100-W WB1B 26kw open vent `S`Plan Control Wiring

    Hi, I have purchased a new Viessmann 100-W WB1B 26kw open vent gas condensing boiler and want to connect it to my existing `S` plan system using cylinder and room stats with Honywell zone valves. I have also brought the digital 2x channel timer. The pipework is stright forward but i cannot...