Search results

  1. R

    Mynute 20e Boiler help pls...

    went out tonight leaving the boiler in the on position with the thermastat turned down to the lowest setting and the pressue at 1.5bar, came back 3 hours later to the pressure being zero, however, the fault light being off and the boiler sounding like it was working ( maybe the fan running).. I...
  2. R

    Mynute 20e Boiler help pls...

    It's been over an hour since my DIY fix and the leak has stopped, however, boiler fault/reset light has been on 6 or so times and I've had to reset it.. On reset it's running for seconds to 15 mins..
  3. R

    Mynute 20e Boiler help pls...

    The expansion vessal has air in it and I also top this up with a cycle pump but dont have a guage to measure what psi it is.. I have just checked the safety relase valve and it's leaking so I guess this needs repalcing .. I've capped it with a smirnoff bottle top and some blue tack and it...
  4. R

    Mynute 20e Boiler help pls...

    Looking for some advice on a few issues I have with my Mynute 20e boiler… The issues: Set the boiler to start At 6am, wake up in the morning and the boiler pressure is between zero and 0.5 bar, the reset/fault light is flashing and the boiler isn’t running. I increase the pressure slightly...