Search results

  1. G

    vAILLANT vcw 282

    It's the overheat reset
  2. G

    Vaillant VCW 221 Pilot Light Problem

    It's on the gas section,it will be a job for a RGI
  3. G

    Vaillant VCW 221 Pilot Light Problem

    Try changing the magnet,vaillant part no.17-0295
  4. G

    Potterton Performa 28, not lit/error led lit up

    Sorry, I meant that this model doesn't have a pilot light...
  5. G

    Potterton Performa 28, not lit/error led lit up

    No pilot light,or way to light manually,is there power going to the pump,is it spinning?
  6. G

    Glow Worm 18HXi - 00 Flashing on LCD display

    Has the potentiometer been left in service mode?
  7. G

    Can you help identify this part please - Worcester Bosch 24I

    Worcester Part no. 87186805270 pipe discharge condensate
  8. G

    Thorn Olympic 38/50B gas boiler...

    Thorn got taken over by Myson,which then became Potterton Myson,which then became Baxi Potterton
  9. G

    Thorn Olympic 38/50B gas boiler...

    If its going to be anywhere it will be in the rope seals on the flue hood,contact Baxi who should be able to tell you for sure
  10. G

    he35 boiler error msg

    Have you pressed reset button? L8 is a fan error,either going to be pcb or the fan faulty
  11. G

    trouble with fitting a new radiator valve

    You won't have to turn the mains off
  12. G

    Thermostat replacement (from 4 wires to 2 wires). (pictures)

    Because the new thermostat is made of plastic it doesn't need to be earthed but the connection is there for joining earths,it won't do anything connected or not
  13. G

    Thermostat replacement (from 4 wires to 2 wires). (pictures)

    Cut off ther bare ends and use insulation tape
  14. G

    Thermostat replacement (from 4 wires to 2 wires). (pictures)

    Earth green/yellow,Grey neutral, red common and black calling,so just connect up red and black.
  15. G

    Thermostat replacement (from 4 wires to 2 wires). (pictures)

    You need to discard earth and neutral,make them safe and connect common and calling into the two connections on your new backplate,it doesn't matter which way round
  16. G

    BAXI 51/5 PCB ??

    Meter across orange and brown on the lead going to gas valve and also red and blue.this will confirm if you have the correct voltage at the gas valve.i'm not sure which is which,one set is the pilot solenoid and the other is the main burner solenoid.you should have 230vac at one only,if you have...
  17. G

    Sealed System Pressures, (hot & cold)

    The expansion vessel is there to allow for expansion but the system pressure will rise when hot and fall when cool
  18. G

    Sealed System Pressures, (hot & cold)

    When you heat water it expands