Search results

  1. S

    Range Cooker Please Help!!!

    The setup you have is fine, as diversity can be applied to cooking appliances, which is 10Amps + 30% of full load. In your case this works out around about 20Amps Steve
  2. S

    mcb size

    Although the 10.5kW is no doubt rated at 240V, I always put in a 45A myself. I take it you have rewirable fuses? It also sounds like you have uprated an existing shower, you really should have 10mm/4mm Twin & Earth cable. Steve
  3. S

    NIC Domestic Installer Assessment At End Of Week

    No problem, had my assessment a few months ago. If you know your assessments are bang on, MAIN BONDING, SUPPLEMENTARY BONDING, COLOUR IDENT,S ON SWITCH CABLES, LABELS ON CONSUMER UNIT (RCD TESTING, 230V, NEXT TEST DUE) your half way there. First he will ask you to describe the work you have...