  1. H

    Worcester heatslave 20/25

    depressurised (again...) pumped the valve up to 10psi, bled and pressurised again to 1 bar, heating has been running on the thermostat for the last 2 hours, and the pressure only rose to 1.2 :-) Thanks John, your a star!!
  2. H

    Worcester heatslave 20/25

    Ahhh... I've done something wrong I think.. I actually depressed that valve and let all the air out! doh! so I switch everything off, depressurise back down to zero, put some pressure back into the tank and repressureise it to 10psi? wow thanks, im indebted burnerman, thanks
  3. H

    Worcester heatslave 20/25

    Hi guys, first thing first, your advice has been invaluable!! I fitted a new pump, well a previously used pump, from ebay. de-pressurised, carefully fitted and wired the new pump, then re-pressurised. Bled the air again from the 3 square nipples, and the bicycle valves, then re-pressurised...
  4. H

    Worcester heatslave 20/25

    Hi guys, thanks for all the advice. Took the top off and loosened the square release valves, as will as the bicycle tyre shaped one, and only got a very small hiss of air from one of them, the rest all vented water, repressurised to just over one bar and fired up again. all the pipes that I...
  5. H

    Worcester heatslave 20/25

    Thanks Slapper, I'll take the top off in the morning, can you tell me what the rad vents look like? do i open them till air/ water escapes? thanks, much appreciated
  6. H

    Worcester heatslave 20/25

    Hi all. I have Worcester heatslave 20/25 around 10 years old, it stopped working yesterday. Seems to be burning and igniting ok, but heating and hot water not working. When I took the from off and switched up the thermostat to fire the burner, it didnt come on.. But when I reset the overheat...