  1. C

    Hi Dan, I shall do that tomorrow. btw how can we control diff temp values from one system boiler...

    Hi Dan, I shall do that tomorrow. btw how can we control diff temp values from one system boiler for UFH + rads?
  2. C

    Hi Dan. been reading few posts of yours and was wondering if you work in North West London...

    Hi Dan. been reading few posts of yours and was wondering if you work in North West London (Harrow)? I've got an UFH circuit + rad zone + unvented cyclinder that needs looking into in terms of the installation
  3. C

    Separate Zone for UFH on Vaillant system

    btw, can it be reversed? is the main controller VRC 470 controlling the UFH and VR81 controlling the CH?
  4. C

    Separate Zone for UFH on Vaillant system

    I just came off the call with Vaillant tech support and their response was: "If using one heating zone (for rads) and one UFH and a cylinder with a System Boiler (newer ecotec 600+ series) then you can use: - VRC 470 (or 470F if needing wireless capabilities) - VR61 wiring centre giving...
  5. C

    Separate Zone for UFH on Vaillant system

    Many thanks for the reply. Another quick one related to the controls. Is it possible to reverse the order? ie the 430 (or 470F) to control the UFH and VR81 to control the rads (CH)?
  6. C

    Separate Zone for UFH on Vaillant system

    Hi Milleniumaire It is possible to know what the final solution was/is on your installation? Thanks
  7. C

    Plz help Boiler & UFH pump not switching off - timer off

    No luck. Tried once more. For now, I have lowered the boiler flow temp to 38 as I think the water in the circuit is higher and the boiler isnt running at the moment, but the pump is. There is some kind of pump/fan running inside the boiler it seems. I am btw in Harrow
  8. C

    Plz help Boiler & UFH pump not switching off - timer off

    I have switched it off 2 times already. Do I need to wait for specific time before switching it back on?
  9. C

    Plz help Boiler & UFH pump not switching off - timer off

    You can see the valve underneath the pump
  10. Untitled

    Untitled

  11. Images

    Images

  12. C

    Plz help Boiler & UFH pump not switching off - timer off

    I do see one on the UFH circuit underneath the pump (looks like its on the return flow), one on the rads pipe going upstairs, one near the water cylinder. Havent seen the 4th one but will check. Is there anything I can check on the UFH valve to confirm if its faulty? I also have switched...
  13. C

    Plz help Boiler & UFH pump not switching off - timer off

    Hi all I have a Vaillant Ecotec 624 System boiler with uniSTOR 210L cylinder. also have a 3 channel hortsmann programmer which controls: a- Hot Water b- Heating Zone 1 - Radiators downstairs c- Heating Zone 2 - Radiators upstairs (both radiator zone are controlled via 2 separate...