    Plumbing layout advice

    Yes that is correct, they use mostly direct passive thermosyphon, where the cylinder needs to be located above the evacuated tubes, water is then fed to the existing hotwater cylinder... which is further heated if need be using immersion heater or boiler. There are issues with this system...
  2. C

    Plumbing layout advice

    Thanks for your quick response. Sorry I forgot to mention this system is in the middle east where you have 300 days of sunshine per year. Thanks again.
  3. C

    Plumbing layout advice

    Hi, I am after some advice on my central heating and hot water system. What I would like is: - One Solar panel if possible. - System fully automated. (i.e. no need to switch on or off any part of the system). - Make use of Solar panels for central heating. - Point out where...
  4. C

    Sony DCR-PC120E tape will not eject..

    Anyone? Help please..
  5. C

    Sony DCR-PC120E tape will not eject..

    Here is the Service manual page:
  6. C

    Sony DCR-PC120E tape will not eject..

    Hi, I have a Sony DCr-PC120E camcorder and when I tried to replace the tape the deck eject mechanism did not pop so I can remove the tape. Now I have searched up and down the internet and I've found several solutions, none of which worked for me. I have no error codes what so ever. I...
  7. C

    Hotpoint WMA40 not spinning

    Well it appears that the Carbon brushes are worn. I will change them and see how it goes.
  8. C

    Hotpoint WMA40 not spinning

    HI, My hotpoint WMA40 washing machine is not spinning at all. Not on slow not on fast. The wash cycles are fine until it gets to spinning. When spinning commences the motor is heard however the drum is not spinning. I removed the rear panel and cleaned the hose and the drain which was...
  9. C

    Potterton Suprima tripping out

    It has not been doing that for long. The thing is the boiler has nebver run for more than 20-30 minutes per day for the last 6 months or so, most of the time I was running out of hotwater had to use the immersion backup. What had happened is that I took the PCB out tightend the...
  10. C

    Sony DCR-PC120E IEEE 1394 firewire problem

    Hi, Thanks for your reply. I am not using an apple macintosh. I have a PC with WIndows XP professional installed. The camera was working at some point however I used a damaged cable, which had a faulty pin (out of place) and when I forced it in, it must have damaged my socket, and when I...
  11. C

    Sony DCR-PC120E IEEE 1394 firewire problem

    HI, I have a sony DCR-PC120E camcorder. The IEEE 1394/ilink/firwire socket appears to be faulty. I was told that to replace it the cost would be £110. And that most likely it is the PCB which would cost £200+ to fix. I am not convinced it is the PCB becuase when I plug the cable the camera...
  12. C

    Potterton Suprima tripping out

    Thanks for your quick response. I jsut updated my post. (last couple of paragraphs). If it is the PCB what shall I do then? replace it with the latest model? where can I find it? and what is the current model? Thanks
  13. C

    Potterton Suprima tripping out

    Well, it seems that I am not the only one after all. My Suprima 50L was installed in January 2003. The item was ordered around November 2002. By December 2003 the lock out problem started. I didnt think much of it then, I simply pressed the reset and it worked fine. I then went on an...