Search results

  1. S

    Scantronic 9427

    Thanks sparkymarka - systems been fine since you sent me a transformer i have taken it apart and cleaned it even changed the code to previously unused pads, but its started to play up again. ill give it one more try and if that doesnt fix it i,ll replace with the newer model if its a straight...
  2. S

    Scantronic 9427

    Hi guys i have a worn keypad. There are two types of 9427. Are they interchangeable? or another option ? if anyone has the blue one in old stock id be happy to do a deal.. thanks in advance.
  3. S

    Scantronic pir disable?

    oh - so I must be misunderstanding how the system works then. I now know if `i arm the system and walk into a PIR line the siren goes off. It does not go off if I use the EE door despite how long i wait before disarming. Normal practice is to ARM and leave within 30 seconds or so. On...
  4. S

    Scantronic pir disable?

    because it sounds OK when I do a walk test.
  5. S

    Scantronic pir disable?

    Handymanjo - The strobe does work - but I noticed the two leds light in tandem, whereas previously they used to blink one then the other. I cant do any testing today as I have to go to office, but can look again tmw. Is there a suggestion as to an upgrade to the panel and keyboard keeping...
  6. S

    Scantronic pir disable?

    sparkymarka - I was not aware - however, I have walked in the EE door, and waited for a couple of minutes whilst the keypad beeped, and whilst the internal bell set off the external siren didnt. Ill do some more tests tmw as it seems to sound under some circumstances. Handymanjo - I'll look...
  7. S

    Scantronic pir disable?

    Handymanjo I just tried that, and hey presto the siren sounded - however I did it a second time and it did not sound outside, even when i triggered all zones one at a time. The panel lit up the zones as they were triggered so I know the PIRs are detecting movement. Same for a third and 4th...
  8. S

    Scantronic pir disable?

    Sparkymarka, thanks, Yes I am aware there is a 30 sec lag between entry and alarm to allow getting to the panel and disarming. What I'm saying is that I open the door and wait, because I want to check the siren will go off. But it doesnt sound at all. Just the inside bell, and i left it for...
  9. S

    Scantronic pir disable?

    Hi guys Well building work completed. System passes walk test, for all PIRS and also bell and siren. When armed though if I access EE door to set off , the internal bell sounds but not the external siren. Anyone have an idea why it should do that ? And any suggestions on panel replacement...
  10. S

    How to remove skylight tape

    Hi guys, anyone know how to remove the black tape that comes with the skylight glass frames? i want to remove it for a clean perimeter, and get the glue off. image attached. any advice from glaziers would be appreciated.
  11. S

    Scantronic pir disable?

    Tnx. It was installed but years ago. Im sure i used the code once to swop out the PIRs. ill tape over it for now and likely replace the whole system in the new year. cheers
  12. S

    Scantronic pir disable?

    Hi, 0 enter 7890. Nothing happens. I expected all leds to flash but nothing.
  13. S

    Scantronic pir disable?

    Hi its a 9427 remote keypad. oo
  14. S

    Scantronic pir disable?

    Hi, can someone advise me please? I am having building work done, and need to disable or remove a PIR for a period. I thought I could enter eng mode and remove the pir to a different location but the code doesnt seem to work (no lights flash). I tried to remove the cover but the tamper switch...
  15. S

    Anyone recognise this Bristan shower mixer model?

    OK, Thanks Denso13 and JohnD. Can either of you confirm that the lever screw comes out normally i.e. anti CW? or CW? The one I have seems to be seized and I dont want to force it unless i,m certain which way it will undo. I mailed Bristan as suggested, but dont expect a response till...
  16. S

    Anyone recognise this Bristan shower mixer model?

    I found this link, https://www.plumbworld.co.uk/documents/1-bristan-colonial-thermostatic-exposed-mixer-shower-installation-guide.pdf Clearly shows access is via the Lever and a grub screw. I just have to find a way to free it up and get the Lever off so I can wind out the grub screw.
  17. S

    Anyone recognise this Bristan shower mixer model?

    Hi Guys Many thanks for the responses. Yep its a colonial 2 by the look of it. Now, I just need someone to confirm I have to remove the handle in order to get at the grub screw then pull the front off the unit. From there I can get a spanner on the valve. I tried to remove the handle per...
  18. S

    Anyone recognise this Bristan shower mixer model?

    hi, Anyone know what the model in the attachment is? I thought it was a 1901 but doesnt have the raised front on it behind the bezel. I'm trying to get to the valve but cannot get the handle to budge. If i remove the ceramic part by unscrewing the cap, there is a long threaded screw, but it...
  19. S

    Delta Vanilla 60 x 60cm Tiles ?

    Hi, I recently ordered these tiles from an online warehouse that said they were in stock, took my order and money. Now a week later and no delivery I have on calling been told they are out of stock for 5 weeks at least. :evil: Does anyone know where I can buy Delta Vanilla 60cm x...
  20. S

    Advice for New floor prep for tiling

    Hi The wall is still present to about 50mm below the FFL. SO once the new S&C screed is put down i intend to put a SLC over everything then the matt, (per BAL) before tiling with SPF. The joins between the wall and the slabs will be covered plasterers fglass tape prior to the SLC...
Back
Top