  1. R

    Dishwasher wont wash - Neff

    Hi am really hoping someone can help me. We have a Neff S4453 dishwasher which has stopped working correctly. When you switch it on and push a setting, it drains as always and fills before starting its cylcle. The problem is it doesnt start its cycle, it just sits there, making a very quiet hum...
  2. R

    Radiator Fan on Constantly

    Thanks for responses - No car does not have air con. Also have changed green sensor, and it made no difference. Disconnected sensor on radiator and it made no difference. Which 2 sensors do you suggest i change - thats is where are they located??
  3. R

    Radiator Fan on Constantly

    Hello Really hope someone can help. We have just bought vw golf SR auto 1.6 2001. Bout a week ago the radiator fan started coming on even when the engine was not hot (after about 2 mins). It would stay on constantly even after engine was switched off for about half an hour. We therefore have a...
  4. R

    Hot water cylinder

    Thanks - yes think I will use copper - sounds a safer bet
  5. R

    Hot water cylinder

    Or are you saying that I can not cap/loop the flow /return at all?
  6. R

    Hot water cylinder

    Sorry im not sure if you are being serious - are Guest a make? - Are you saying do not use Hep to cap off or create loop? - Im a bit confused now - Please help
  7. R

    Hot water cylinder

    thats brill - thanks so much
  8. R

    Hot water cylinder

    Thanks so much for your response - can I just ask one more thing - can I use plastic Hep pipe to link/cap flow and return (as it is temporary) - or will it melt as it will be fairly close to the boiler thanks again
  9. R

    Hot water cylinder

    Wondered if this brilliant site could help me. I am refurbishing a property which has an old floor standing boiler, with gravity hot water (via coil to cylinder) and pumped heating. I want to temporarily remove the indirect cylinder, but be able to keep the heating on (hot water does not...
  10. R

    leak from automatic air vent

    thanks so much for you help
  11. R

    leak from automatic air vent

    thanks for such a speedy reply - Yes I have drained system down before - so I should replace the whole bit? - would you mind explaining what the likely cause of this vent leaking is? - cos i will check the other one while i am at it - also when i change it - the cap should remain loose yes?
  12. R

    leak from automatic air vent

    Hello, used this site last year and was a great help, hoped someone could help again. I have a sealed heating sytem using a combi boiler. Up in the loft there are a couple of automatic air vents (bottle air eliminators - I have heard them called) fitted to the top of 15mm vertical pipework - I...
  13. R

    Lockshield in room with thermostat

    thanks so much - you are a star
  14. R

    Lockshield in room with thermostat

    I am really sorry to be thick, but if I balance one in with the system, wot do I do with the other one?? fully open/closed/half? your help so far is appreciated
  15. R

    Lockshield in room with thermostat

    thanks for your reply. Should it be balanced on both valves or just the return side like the others with the flow valve fully open?
  16. R

    Lockshield in room with thermostat

    Hello hope someone can help me. Have just changed all my rad valves with TRVs. I have left the rad with the room stat with 2x lockshield valves. I have adjusted the lockshield valves of all the rads with new TRVs according to their piperun from the boiler. My question is regarding the rad with...
  17. R

    Honeywell 2 port Valve

    The auto/man lever definately has no spiring or resistance at any point, it is completley loose. I guess i will have to drain down and replace - thanks everyone
  18. R

    Honeywell 2 port Valve

    thanks for all your comments, just a bit confused. The manual/auto lever does nothing it just moves freely, with no resistance. I am assuming it is stuck on open, as the pipework on either port have been hot. Can I drain down and just change the actuator head with motor(if the valve itself seems...
  19. R

    Honeywell 2 port Valve

    Thanks for that. This one def has no dimple, and when casing off seems to have 3 of 4 screws holding the head to the valve. Do I therefore have to drain down?? Also when the room stat calls for heat, the motorised valve seems to be stuck open(could have been stuck for a while) but now it...
  20. R

    Honeywell 2 port Valve

    I have to replace a Honeywell 2 Port Valve. I was told that some of the 3 port version have a nipple on the casing which means you can replace the motorised section without draining the system. Does anyone know if this is the same with the 2 port. The one i have has no nipple, so want to be sure...