I’ve fitted the lintel and tried to tie in the bricks above the fire back that were sticking out. This means there’s a half brick to the rear unsupported if the fireback was to be removed. I’ve attached a picture prior to mixing up the muck. Currently a 100mm bearing each side, but this will...
Thanks. Could turn into a pig of a job. If the bricks drop, above lintel area, no way of putting them back in.
Any suggestions on where to go from here? Think I’ll fit the lintel tomorrow, at least the face will be supported as removing timber frame
I’m not certain but could be. They don’t seem to be tied into the back of the chimney though, which is strange.
Was thinking of getting fireback removed and getting bricks fitted along the face and under the current ones that are on the fireback. This would create the right size opening...
Hi all
Looking to get a gas fire fitted in an opening that was already present. Upon further investigation the opening was made smaller by a timber frame (gas man said has to be non combustible material).
I’ve ripped this all out and looking to get a new lintel installed and the fireplace...
Hi all
Currently have a Vaillant 637 system & Telford unvented cylinder controlled using Hive. Looking to move to Vaillant controls to allow better control & modulation with weather comp. There seems like a lot of options and wondered if someone could help with the items I need. Would like to...
Hi all
Just fitted a vertical rad with an in-built divertor and after piping up I think I’ve I got flow and return mixed up as only the bottom is heating up, so bypassing the divertor
Can I drain and fit an a divertor on the other side to fix this or do I need to re-pipe this?
Thanks in advance
Hi all,
Got some large holes where old bushes/tree's used to be and wanted to know the best way to fill these before reseeding the area. I've read online about using sand but there was no mention as to which sand.
Many thanks in advance
Hi all
A few days ago my fridge freezer decided to go warm and had to throw everything away. Since emptying it, it seems very sporadic and at time works fine and cooling ok (4degC fridge) and other times it gone to 16degC
Any ideas what could be causing this?
Thanks in advance
It was propped up. Definitely moved as can see gap in the top of tile detail and the brick now touches the new frame in the middle where there was a gap
Yes the render will need to be sorted as well. The bricks should just pop out, but luckily I have 5-10 matching spares if needed for the header.
I’d prefer to keep the look as it will match other window details
Yes quite possibly when the old window was installed. Wouldn’t be keen on non galvanised steel as it would just rust.
I’ll get some quotes to install a proper lintel. Thanks woody