    Bypass valve location

    Thank you very much for all this insightful feedback. It seems my first step needs to be to find out why the ABV never closes - either a faulty ABV or debris inside.
  2. S

    Bypass valve location

    Regarding the Tacosetter, I understand this is a fixed valve that sets the flow rate in the bypass, but with a visual display of the flow rate value. In effect I do have the same arrangement today with a fixed valve (but with no display) + ABV in series; so currently I am setting the fixed rate...
  3. S

    Bypass valve location

    I don't know whether the bypass is only required when the boiler shuts down. Vaillant's installation manual specifies an ABV and does not mention a motorised valve to control the bypass. Also an ABV implies (to me) that the bypass is meant to respond variably as the TRVs close, although I...
  4. S

    Bypass valve location

    Hi, regarding the pump mode, this has varied as follows. Background: My house is on 4 floors - the boiler/pump/MVs/DHW cylinder are in the basement, while the top floor rads are about 9m above. The UPS3 pump has Constant Speed 1-3, Proportional Pressure 1-2 and Constant Pressure 1-2. There have...
  5. S

    Bypass valve location

    I have a similar question about the bypass valve location. My system comprises a new Vaillant heat-only boiler, pressure vessel, DHW cylinder, 3 Motorised Valves (1 x cylinder, 2 x CH zones) and 15 rads with 12 TRVs. Vaillant specify an Auto Bypass Valve (ABV) is fitted no less than 1.5m from...