Search results

  1. D

    complicated boilermate2 system

    yes there are 2 pumps in total on this system, 1 for heat exhange from boiler and one to pump rads...........
  2. D

    Disaster - maybe

    oh yeah and that!!!! also to allow kitchen fitters and heating engineers to become more qualified than sparks unless you cough up ridiculous amount of dosh ! and they still do it wrong...... ive just rewired a kitchen for someone that was done by kitchen fitter... 2.5mm radial from db 30amp...
  3. D

    Pendant light

    yes it will be fine......if your that worried get a piece of heat sheathing and slide it over cables.... the light isnt anywhere near anyway is it?
  4. D

    Another Garden shed wiring project.

    dont even need to look at this to know it needs complete rewire my friend, maybe the cows wont be moving out for a while....get plenty of quotes as so many wrong uns out there trying to bolt people up especially with part p now gives em excuse to hike it up a bit..........
  5. D

    Disaster - maybe

    so why was part p etc brought in again...... :|
  6. D

    Security lights - need an isolator?

    also bear in mind if your coming direct off ring without fused spur then a) you have to isolate mcb which means everything on that circuit goes off when changing lamp b) ring is likely to be on rcd which could be tripped by water getting into fitting especially if its a cheapy c) you need...
  7. D

    Pendant light

    can you get access to floor above light? if so get yourself a junction box to terminate existing wiring into that is already there and just pick up your switch wire ,neutral and earth to limit the amount of wires in the brass dome.... the earth block i assume you mean is already on the fitting...
  8. D

    complicated boilermate2 system

    im going to electrical section now to see if i can help someone out, it will make me feel useful spreading what i know rather than pulling my hair out with this for a bit.... :cry:
  9. D

    complicated boilermate2 system

    its in the loft and the cold feed from f&e tank is bottom outlet so yes the water is over it . i have tried blowing into this via hose to see if anything happens but i cant even blow which suggests that it is full does it? i have a guy coming to look at it thursday afternnoon so ill keep ya...
  10. D

    complicated boilermate2 system

    i didnt have a problem i was attempting to fix it was simply a case of draining system to cut 2 new rad valves in for a towel rad, when i turned the water back on to refill i got an air block which burnt out a pump which is now replaced, the air vent on the heat exchange pump wouldnt draw it out...
  11. D

    complicated boilermate2 system

    i have just drained my boilermate2 with glowworm ultimate boiler system down to change a rad valve, had to backfill system as got airlock in on restart and couldnt draw it out by opening vent above pump...also put new pump in.... now my boilermate atom bomb thing(!) in airing cupboard is making...