Search results

  1. I

    Ring main Or Radial

    Hello, I have a very small cottage that I am going to renovate which will include a total rewire (yet to find lecky)and replumb. Currently the kitchen is a very small galley type and will have only a 2m wall that I could have sockets put on, Just two double sockets will be all that I can get...
  2. I

    Dot and Dab?

    Hello, Just bought an old stone terraced house. The walls have quite a lot of hollow patches and some mortar has also come away. I was going to hack off all walls and dot and dab strait onto the uneven stone walls, after giving it a coat of pva. But, a friend suggested that the walls should be...
  3. I

    gen 4 alarm entry and exit

    Hello can anyone help me please? I have just installed an Accent gen 4 with seperate lcd key pad. Front door on zone 1 which is timed,hall on zone two kitchen on zone 3 living room on zone 4 and back door on zone five,Now the problem..... I have programmed zone 1 to be timed,zone 2 to...
  4. I

    Reducers on each side of a pressurereducing valve

    Hello, Could anyone tell me if it is OK to use reducers at each end of a pressure reducing valve in order to couple up to 15mm pipe work. Thanks
  5. I

    space for a en-suite

    Hello, Can anyone tell me the minimum space I need around a toilet /basin and shower.i want to install a small en-suite and am thinking of a corner toilet a small cloak room basin and a 1000mm x 760mm shower tray which I already have.It is being fitted in a new extension and will have to...
  6. I

    New block walls

    :( Hello can anyone give me some advice? I have got a builder that comes highly recommended and has started my double story extension(4mx6.5).He usually uses a team of brickies to get up the blocks but because they are stuck on another job due to the weather holding them back he has started the...
  7. I

    celcon thermolite blocks

    Hello,I would be grateful for some pointers.Can anyone tell me if the celcon thermolite blocks are ok to use under strctural beams.I have two rsj beams (3m span)carrying the upstairs both skins on the side wall of the new ext ,one end of these beams will sit on a piller and the other will sit on...
  8. I

    Extending heating system into new extension

    Hello, can any one give me some information? I intend to extend my heating system into a new extension .Currently I have a 22mm flow and return going around the house with t offs of 15mm and then down to 10mm to the different rads. Can i just T off the 22mm flow and return and take them into...