Search results

  1. M

    Boiler manufacturer states must have annual service

    I think we are all missing the point here, this is a case of consumer law in the first 12 months after purchase you are covered by statutory law anything beyond that is deemed a gift from the manufacturer and as such they can attach conditions as they see fit. Regardless of your feelings toward...
  2. M

    Techflow QT80 T - Loft location possible ??

    Hi i'm sorry to say you can't put that pump above the cylinder as its designed for water to fall into it and be pushed out it wont suck it up my friend got one cheap off eBay and we tried, the cold water worked but the hot kept sucking in air (despite having a tech flange and anti gravity loop)...
  3. M

    Hi Bri If you give me your no I will give you a call you can email it to [email protected]...

    Hi Bri If you give me your no I will give you a call you can email it to [email protected] cheers Paul.
  4. M

    Hi Beezo I am a gas engineer I hold my own registration van tools etc I live in Widnes, I'd...

    Hi Beezo I am a gas engineer I hold my own registration van tools etc I live in Widnes, I'd like to know more about your proposition cheers Paul.
  5. M

    HELP WITH WILY PUMP

    It worked fine on the boiler when I swapped them over so should be ok (mines still running 18 months on) Paul.
  6. M

    Ideal icos HE15 problem

    Sounds like a 2 or 3 port valve problem to me the C will display for HW as well as heating sorry take a picture of the valves usually in the airing cupboard that might help Paul.
  7. M

    HELP WITH WILY PUMP

    Hi its possible to swap the control box from your old pump to your new one, undo the 2 phillips screws shown in your picture and the control box pulls off. You should be able to then swap them over just check they are the same I have done this myself and it worked fine Paul.
  8. M

    New boiler installed on an old system. Bodged job?** PICS **

    As I said in an earlier post we cant really comment on a job we haven't seen. If your system was a combi system from new correctly installed and inhibited then its possible that it was clean enough and didnt req a power flush. The installer may have flushed it hot and cold its quick and easy to...
  9. M

    Warm front Installation due, Boiler / Radiator questions

    Hi first you say you dont want the Ideal as its unreliable what are you basing that on? I have fitted 50+ ideal logics and had 1 fail due to a faulty spark gen(which is fitted by but not made by Ideal) sounds ok to me. normally all waste is removed but if you wanted the old rads etc you could...
  10. M

    New boiler installed on an old system. Bodged job?** PICS **

    Without seeing the job its difficult to advise, it may be that the system was clean and did not require power flushing. Its normal practice for the warm front installer to fit a system filter did he do this? All warm front installations are quality checked post installation you should raise your...
  11. M

    boiler fans

    Hi your post is a little confusing do you mean you had a venturi replaced then later the fan failed and that was replaced ? In a lot of boilers there are seperate venturis which disintegrate (Ferroli and Vokera for example) and can be replaced. its possible that your fan required a new venturi...
  12. M

    Neighbours noisy boiler, what are my rights? Any advice?

    Hi rather than contacting the council which can cause problems should you want to sell your house perhaps you could offer to help with the cost of a service for the boiler, it may not be an ideal solution but probably better than all the stress it seems to be causing you hope this helps Paul.
  13. M

    worcester 240 rsf boiler keeps cutting out when shower on

    Hi dont want to be the bearer of bad news but it sounds like he's right,they can also be cleaned but you might not find anybody willing to do that hope this helps Paul.
  14. M

    Some taps calls for hot others dont

    Hi I would say you need a new diaphram its available on ebay quite cheap and an easy diy fit just search on here for it theres loads of threads hope this helps Paul.
  15. M

    thermocompact vaillant is always over pressured

    Hi sounds like your expansion vessel needs pumping up search on here for expansion vessel you should find all the info you need hope this helps Paul.
  16. M

    Need a gas fire installing.... Dudley

    Hi nobody can give a price without seeing whats needed, if you go to the gas safe website you can find gas installers in your area Paul.
  17. M

    baxi105e c/h not working

    Hi I would check your external controls clock/stat first more often than not this is the problem hope this helps Paul.
  18. M

    Baxi 105e sticky pin on CH differential valve

    Could be dirt in the valve theres a service kit available for them it probably needs stripping and cleaning its not to bad a job if you have good access.If dirt is a factor you should clean the system hope this helps Paul
  19. M

    Please help - Central heating issue.

    Hi do you still have hot water if so you might have gravity hot water and pumped heating if you do the pump may have failed, theres no internal pump on a bbu that I know of so its probably hiding under the floorboards or boxed in beside the bbu this would be the first thing to check hope this...
  20. M

    3 years of air in sealed system and now a leak

    No the isolators under the boiler( the 2 outer ones) this will isolate the boiler from the pipe work and if it still drops then the boilers at fault if not im afraid its on the pipe work somewhere, hope this helps Paul.
Back
Top