  1. P

    Replacing room thermostat - Wiring?

    Hi Dishman Have a look at the Drayton Mitime programmers with wireless room stat - which solved my problem, I picked the T720R on ebay for £45.00. I had a similar issue with a radiator in our hallwall that had to be left off, as the room stat was in the hallway, causing the lounge & the...
  2. P

    Magnacleanse connection via Fernox TF1

    Dan...... It wasn't aimed at other installers, plumbers just the installer that fitted the boiler, it was just a rant....
  3. P

    Magnacleanse connection via Fernox TF1

    Thanks but the installer was supposed to be professional, cannot trust them, shall only use a for Boiler servicing only, that way I know it's been done correctly by myself Had to purchase the Fernox flushing adapter as the elbows were too big to fit one side by side Have now cleaned the...
  4. P

    Magnacleanse connection via Fernox TF1

    I had the TF1 installed from when the I had the boiler installed 3 years ago but have been having problems with kettling & have had to add 3 different lots of x800 to get the system clean The system was power flushed including the magnacleanse which the installer used, I'm not convinced that...
  5. P

    Magnacleanse connection via Fernox TF1

    Finally picked up the Magnacleanse, it appears to have 3/4" & 1" BSP fittings 3/4" 1" The Fernox TF1 uses 1" fitting so I have ordered 2x 1 Inch BSP Brass Male x Female Elbows to connect to the TF1 isolators Will update the post when I have the Elbows to confirm that it fits
  6. P

    Magnacleanse connection via Fernox TF1

    Thanks Rich, is there another way of connecting it without one of those (i.e. elbows, hoses, reducers) as they are about £65 Adey state they can work alone without a powerflush, simply closing of each rad in turn & using the VibraClean, have watched a few vids doing this without a powerflush
  7. P

    Magnacleanse connection via Fernox TF1

    Thanks..... it's a Magnacleanse not a Magnaclean
  8. P

    Magnacleanse connection via Fernox TF1

    Hi Just managed to get a Magnacleanse complete kit 2nd hand which I collect tomorrow I have a TF1 22mm installed & want to connect the Magnacleanse via the TF1 isolator valves Please could you advise how I could connect this up as I’ll need to buy some extra bits to connect is up, I...
  9. P

    Vaillant "D" Settings help

    Hi Have now filled the system & added x800 left for a 3 days cleaning out the TF1 at the same time Drained the system & flushed through & refilled & ran the system for 4 days with just water Drained the system & took off all the rads & flushed them through with a hose until clear...
  10. P

    Pump sticking - taking it apart

    Thank you so much........ that's really helpful :)
  11. P

    Pump sticking - taking it apart

    Should the surfaces be smeared & seals or just the seals? Would this grease do the job? http://tinyurl.com/lj3b4ok Many thanks
  12. P

    Pump sticking - taking it apart

    Hi Having issues with a 3 year old Wilo pump sticking, probably due to sludge as I'm currently cleaning the system out with X800, then changing the pump to a new Grundfos when completely clean Just want the pump to run for a few more days before I change it If I take the pump apart &...
  13. P

    Vaillant "D" Settings help

    Taken from the sentinel website
  14. P

    Vaillant "D" Settings help

    Many thanks I do appreciate your advice I live in a very hard water area would it not help, long term to put x200 in or is it wasted?
  15. P

    Vaillant "D" Settings help

    FYI https://www.youtube.com/watch?v=AAZhPYkYUE8
  16. P

    Vaillant "D" Settings help

    Hi Scoobydo Many thanks for your reply It's the only thing that hasn't been replaced as yet from the old system, so would that be the reason why the temps go up so quickly Is there a way to test the MV being slow? I've not sure which plan I'm on, just had a look on Wiki & I think its...
  17. P

    Vaillant "D" Settings help

    Cheers, what cleaner would you recommend X300 x400 or x800 or just drain & flush with clean water? Would a Grundfos UPS2 15-50/60 130 or the Grundfos Alpha 2L 15-60 be the one to go for? Many thanks again for your advise
  18. P

    Vaillant "D" Settings help

    Many Thanks, what would you suggest I tried 1st change the pump? If so can you advise which Grundfos pump to buy?
  19. P

    Vaillant "D" Settings help

    OK hope this helps, did as stated in chimney sweep mode all rads on with TRVs open D0 is at 7KW turned it down on advise from engineer due to the kettling Values D40/D41 starts @ 28/18 1 min 27/17 2 mins 30/20 3 mins 33/23 4 mins 35/25 5 mins 37/27 6 mins 39/29 7 mins 41/32 8...
  20. P

    Vaillant "D" Settings help

    After just firing D40 shot straight up very quickly was at 49 after a few seconds it was at 63 D41 was at 49 As far as I'm aware the pump doesn't have an option to change the pump self modulating or constant flow ?? I do hear the pump sometimes slow & speed up, even though set to...