Search results

  1. R

    Camray Quartet broken

    Fan now replaced (takes a while since I have an issue with getting deliveries during the day when signatures are requierd). Anyway old fan looked fine, certainly fine at the oil pump end but clearing something was amiss slightly inside (I presume a bearing but have not opened it up to see...
  2. R

    Camray Quartet broken

    yes I got that part first, that's when I realised there was a groove in the spindle and the old one was slipping on it.
  3. R

    Camray Quartet broken

    I ordered a new fan motor, I can look at taking apart the old one later on to see if it can be salvaged for an emergency spare part (I often get snowed in for a couple of weeks so I like to spares for some things (like my water supply pump) anyway. Thanks for the epoxy tip. Just hope the...
  4. R

    Camray Quartet broken

    Problem identified but not solved yet The problem is the fan, what is happening is that it is slipping on the motor spindle and jamming against the metal cover (which does exists and is a sort of clamshell case secured by 3 screws). Looking closer at the spindle of the motor it looks like...
  5. R

    Camray Quartet broken

    I am removing the cast cover head time to get to the fan. Tonight I replaced the old one while waiting for a new one to arrive (the part number actually ends in 88 not 08) After hitting the fan a bit to make sure it is true (I bent it a little trying to remove it) the heating is firing up...
  6. R

    Camray Quartet broken

    The kind man from Riello has emailed me a parts list and manual for the boiler, it seems it is a G7Q Reill0 40. Certainly the parts diagram seems to match the bits of the boiler that are visible. The only real difference is that I don't have the metal cover, but thnking about that I may...
  7. R

    Camray Quartet broken

    Anyone have any idea on how I can find out what type of burner I have, It is a reillio but I can't find any markings that would indicate a model number that I can relate to What is legible on part of it is G7Q, type 459T55 and there is a code 01407206364 On the housing for the fan there...
  8. R

    Camray Quartet broken

    The motor is only stiff on some occassions and frees up fairly easily but this is only the case when the whole assembly minus the cover is installed. Without the impellor I have not yet seen the motor stick but with and without the cover I have seen the motor stick when the impellor is fitted...
  9. R

    Camray Quartet broken

    Thanks for the reply I don't really see it being an oil pump issue, either the fan fails to turn (and it is not as free to turn by hand as it is other times) or the fan turns and the burner then ignites with no issue whatsoever a few seconds later (as normal). Unless there is some...
  10. R

    Camray Quartet broken

    I finally did get the impellor off but the motor still seems to be sticking. Without the impellor on the motor starts fine it seems, with it on it seems to stick (moved fractionally, more like a judder stops and then the unit will lock out a little later). I originally did try replacing...
  11. R

    Camray Quartet broken

    My boiler is not working, after one repairman who swore blind it was the central heating pump (yes really) and one who would not fix it but now only did new installs (at £3000) I have run out of people willing to come to my rural location and am looking at the unit myself. The issue is with...
  12. R

    HOAT Antifreeze

    Can someone point me to a UK online supplier of a HOAT based antifreeze, so far I can only find OAT versions (such as Halfords) and some searching has indicated that this would not be a good substitute long term.
  13. R

    Sewage Smell but no dry traps.

    Can I make a suggestion albeit from a non professional and sheer guess work basis. With the absence of a soil stack and venting could it be that you have replaced a toilet with one that has a lower volume of water in the trap? If that is the case would it not be possible that the pressure...
  14. R

    Soil pipe fittings external wall help needed

    It is two seperate pipes coming from the wall and two seperate underground connections ready for them (different walls on what was an extension). Both of these btw are 1st floor. Existing bathroom and toilets are connected to a stack that is internal to the house and not able to be joined...
  15. R

    Soil pipe fittings external wall help needed

    The underground connections are all soil ones have already established that.
  16. R

    Soil pipe fittings external wall help needed

    The situation is that I am trying to complete some work that was started on the house I bought but abandoned prior to my purchase for various reasons. The current situation involves the completion of some new soil pipe works. Internal pipes are not an issue and have been done (although not...
  17. R

    Replacing one consumer unit with two

    The power from the supply cabinet (first set of pictures) as you can see goes through the barn wall the switchover box. Only use this for power cuts when I need the generator on. After that the other pictures in set 3 are for the power to the barn itself and a couple of small outbuildings, no...
  18. R

    Replacing one consumer unit with two

    and the final set is the bits before the house but after the meter
  19. R

    Replacing one consumer unit with two

    set number 2 is the consumer unit in the house
  20. R

    Replacing one consumer unit with two

    ok some piccies set number 1 is the supply cabinet.
Back
Top