Search results

  1. D

    Potterton Profile 60e intermittently wont ignite

    Thanks HarrogateGas, that was a perfect diagnosis. I got in a professional and he diagnosed the gas valve stuck open for the pilot as you did. He believed this was probably also confusing the PCB causing the other behaviour. He replaced the gas valve and now the pilot light is out and only...
  2. D

    Potterton Profile 60e intermittently wont ignite

    I've also noticed the pilot light remains lit at all times, even when I power off the boiler. Reading other notes in this forum for other profile 60e's the pilot doesn't light until it is ignited. I had an engineer out a couple of years ago to replace the PCB as it wasn't igniting then.
  3. D

    Potterton Profile 60e intermittently wont ignite

    Hello I'm wondering if someone could provide some advice. I noticed the other day my boiler (Potterton Profile 60e) didn't sound right. Intermittently the boiler doesn't ignite. The pilot light is lit and the sequence starts with the fan going and I hear a click but then the fan stops and...
Back
Top