Search results

  1. M

    Glowworm Compact 80E No Ignition

    Thanks I'll give a local corgi a shout to set pressures up :D
  2. M

    Glowworm Compact 80E No Ignition

    Just to wrap this thread up:- Changed PCB and now all working. Got PCB from ebay it was an updated version which included a replacement DHW thermistor to mount on internal pipework in boiler replacing original thermistor unit mounted on diverter valve. Hot water performance has never been...
  3. M

    Glowworm Compact 80E No Ignition

    Ok I now have refitted PCB between Red and Blue I have 55Vac when ignitors firing. Going to try new PCB. Cheers for your help guys
  4. M

    Glowworm Compact 80E No Ignition

    Cheers rob884 I have 1.6K black to white and 2.6K Red to Blue Are these the two solenoids? If so they're not shorted or open I'll refit PCB and power it up to test volts :D
  5. M

    Glowworm Compact 80E No Ignition

    My Compact 80E has stopped igniting. It goes through the fan sequence and the spark ignitors fire with DHW and CH demand OK but no flame. I am assuming that the gas valve is not opening. The PCB looks to have a section next to the transformer around the rectifier diodes where it has...
Back