  1. N

    Is my PCB broken ?

    If anyone's interested........... After a few more measurements on the board (e.g. 3V across the fan power relay instead of 24) came to the conclusion it was knackered. Replaced it for 100 quid (inc VAT) and everything is OK now. The layout of the new PCB has quite a few changes since the...
  2. N

    Is my PCB broken ?

    It 'reads right' at that point.
  3. N

    Is my PCB broken ?

    As I said originally by 'responds' I meant it switches over. having two states, one without positive air pressure and one with the air pressure. So it starts off in the no pressure state, and when the fan is on, it switches over. So: The air pressure switch is in the correct state to...
  4. N

    Is my PCB broken ?

    the reason for powering the fan manually was to see whether it was just the control of the fan which was faulty.... and to be sure that the pressure sensor & circuits were actually OK as suspected. there's no problem at all giving the fan the voltage it is rated at, whether that is from a...
  5. N

    Is my PCB broken ?

    yep, it switches over when the fan runs. so if I power the fan (separately so it runs) and turn on the boiler then i get to a different fault. i don't get any ignition, and eventually the error code is 'no flame detected'. I can hear a few relays (there are several close together) clicking...
  6. N

    Central Heating Expansion Overflow

    sorry to crash in but I have a bit of a related question relevant to this thread - what about sealed systems (e.g. combi boilers). can you rely on the system to push the air around enough and bleed it off at the radiators or the pump ?
  7. N

    Is my PCB broken ?

    I've got no heat or hot water from my Chaffateaux Britony Combi boiler. I power it on & ask for HW or CH (same symptoms happen) Pump starts ok, but fan does not. Eventually it displays an error code meaning the "air pressure switch is not responding with the fan on ". But the fan is not...
  8. N

    Poor flow in C&M Britony Combi boiler

    any ideas - anyone ? Will the pump (grundfos 15-50) be unhappy if I reverse the flow through it when flushing it out ? Will the fernox cleaners clean out any dregs in the pump ?
  9. N

    Finding gas leaks

    Have you checked this with the gas tap to your boiler closed off? Not just with it off ? This would rule out a leak in the boiler (unlikely I know) You might have some cast iron piping, which was used before copper. Cast iron is very slightly porous, which could explain what is going on...
  10. N

    Poor flow in C&M Britony Combi boiler

    The boiler was working ok last night ! The pump works, and as far as I can tell the various sensors work ok. Since neither the HW nor the CH work I guess that if it is a flow problem which the boiler is detecting, its the primary heat exchanger. I drained the boiler (not the whole system) and...
  11. N

    Poor flow in C&M Britony Combi boiler

    I have a Chaffeatux & Maury 'Britony' Combi boiler which is less than two years old but isn't too happy. It won't fire, and following the diagnosis chart, it looks like there is insufficient flow in the heat exchanger. Could this have scaled up or sludged-up within two years. Don't know if...