    Soil Stack Rodding Eye

    Is one required to the junction where it meets the soil stack or is rodding from this point (screw cap) adequate for getting around the junction?
  2. 4

    Soil Stack Rodding Eye

    Could anyone advise on where a rodding eye should be located to first floor WC's to allow for rodding in the event of a blockage? Sketch illustration below.
  3. 4

    Soil Stack Maximum number of toilets

    Can anyone advise the maximum amount of toilets allowed one soil stack can take? Thanks
  4. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    Water pressure is fairly high here, showers are gravity fed and like a power shower. Will try the gauge hopefully that will be an end to this.
  5. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    Ok thanks, will get a new pressure gauge. Does the gauge dictate to the boiler when the filling loop cuts off as it stops filling at 1 bar on the gauge?
  6. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    Ok replaced the vessel however there is still water discharging outside. Only thing I can think of is the pressaure gauge, it doesnt really move from 1 bar and has been on the past hour. Checked the nipple on the PRV and it seems to be fully in so there is only minor leakage. Also when...
  7. 4

    Where to buy replacement board..Ideal classic

    http://www.partscenter.co.uk/parts/index.html
  8. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    Thanks for the reply, that explains it. The expansion vessel diaphragm had split as there was coming out the air valve when checking its pressure. Hope to have this sorted tonight.
  9. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    Took the new PRV off, clean as a whistle and returns to seal. Gauge returns to zero when the pressure is released in the boiler and cuts off the filling loop at 1.5 bar reading. Will fit my new vessel tonight and take it from there as the vessel was definately faulty.
  10. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    Odd, the PRV was changed and only ran a few minutes before I realised the vessel had gone.
  11. 4

    Expansion Vessel Why does it leak water out of PRV below 3 b

    My expansion vessel is being replaced as water comes out the air valve. However, even when the pressure is below 3 bar there is water that leaks outside, why is this if the PRVis not supposed to open until 3 bar? Thanks
  12. 4

    Leak from Ideal istor Boiler

    Just checked my PRV outside, theres water leaking out of it at 2.4 bar pressure. Assume that I should replace the valve?
  13. 4

    Leak from Ideal istor Boiler

    Hi I finally got my boiler sorted with its electrical problem however a dodgy connection on the pump caused the boiler to shut down (heat exchange overheat) The connection was easily fixed however I am having problems with the pressure in my system. The cold pressure is 1 bar and when I...
  14. 4

    Ideal HE Boiler Hot water but no central heating

    The external control is right outside the boiler cupboard and is calling for heat. How do you check the 230V connection and where do I look? Thanks
  15. 4

    Ideal HE Boiler Hot water but no central heating

    Hi No C on the display. Nothing happens at all.
  16. 4

    Ideal HE Boiler Hot water but no central heating

    I have an Ideal Boiler HE as shown on the following link. http://www.idealboilers.com/istor_he.html A while ago the pilot went out but wasn't too worried as it was the summer, however as winter is approaching the central heating needs to come on. However, I go through the procedures to...