  1. M

    Ikea kitchen sink waste.

    Due to having a small kitchen, I am fitting a 500mm sink unit with sink to fit. The waste system supplied is huge, will be a struggle to fit & will leave little room for anything else in the cupboard. Any suggestions please for a smaller waste system which will drain sink/ overflow & washing...
  2. M

    Certification. How long?

    Hi. Had notifiable work done by NICEIC registered electrician. How long should it take for paperwork to arrive? Thanks in advance.
  3. M

    4mm2 HO5 RR-F

    My new hob specifies 4mm2 HO5 RR-F (Ikea/ Whirlpool hobs). As advised previously on here, I tried Rexel Senate, CEF & Edmundsons. None of them stocked it. However...the nice chap in Edmundsons said they were getting repeated requests for this now & after my request are ordering 100m. Result!
  4. M

    Fused spur to washing machine & socket. Modification.

    Hi, I have a 13amp fused spur feeding a single socket & flex outlet to washing machine. Both are behind the washing machine. I would like to remove the single socket & fit a terminal block (15 or 30 amp?) to feed the washer FO & a new double socket above the worktop. The terminal block...
  5. M

    Electric Hob Flex

    Hi. I have 6mm cable from CU (32a MCB) to Cooker Switch, then 6mm from CS to Cooker Outlet Plate. I need some clarification on the flex I need from the COP to a 6.5kw Ikea electric hob please. No recommendation in the instructions. These are made by Whirlpool & on checking a similar hob on...
  6. M

    LED under cabinet lights.

    Got these from Maplin. http://www.maplin.co.uk/white-decorative-led-strip-lighting-383747 Kitchen units are not installed yet. Would like to fit these under wall units. The transformer is in the 3 pin plug supplied. Instructions describe it as a low voltage (12V) adaptor. My...
  7. M

    Oven Flex Outlet

    Hi. I have a new Ikea electric single oven & hob. Wiring from CU is 6mm T & E to CCU with socket. I've wired CCU to hob with 6mm T & E. For the oven I've wired 2.5mm T & E from CCU to a 13 amp fused neon connection unit, then 2.5mm T & E to a 20 amp flex outlet. Oven is 13 amp, 2.4 Kw &...
  8. M

    cracks in plaster over pipes

    I recently had new radiators fitted with the pipes chased into the walls. The walls are painted plaster & looked fine until I put the heating on when cracks appeared either side of where the pipes are. I've tried repairing the cracks several times with filler/ paint, but each time the heating...