  1. S

    System boiler without cylinder?

    hi Just looking for some guidance if possible, we have a greenstar 24i junior WB boiler - and a megaflow uncented cylinder in the loft. We're about to have a loft conversion done - and I'm about to start arranging for a plumber to sort out the boiler and tank whilst the work Is done. The...
  2. S

    Worcester 24i with megaflow Power issue

    We have moved into a House with a megastar 24i and megaflow tank. It seems when the hot water is off - the boiler is off - and we don't get any heating! If we turn the water on - the boiler springs into life and the rads get warm! Presuming this isn't by design? Is it just a fault?
  3. S

    Advice on Worcester 24i and Megafloe

    Hi all I'm looking for some advice on a WB greenstar 24i with a Megaflow tank. We just moved into the house and I'm not sure the most efficient way to run the system... Do I leave heating and water on 24x7? Should the boiler be set to maximum? Apparently when it is on full - in the...
  4. S

    Gledhill Boilermate OV and ICOS HE12 - not working together!

    Hi We currently have a boilermate OV upstairs, and a HE12 in the kitchen in a Wimpey house. We have been in for over a year, and all has been well... Until last week. We noticed a leak under the ICOS, so an engineer came out and tightened the pipes. - he swears this is all he did...
  5. S

    adding room stat to qe2 programmer on gravity fed

    Hi I am looking at adding a room stat onto out current programmer - the qe2. Please can someone tell me if i will have any problems due to the fact that - as our system is very old - the heating and water are linked, and come on together.( You can only have the hot water on it own - or at...
  6. S

    Changing thermostat on Boiler Mater A

    Hi Im trying to change a room stat on a Boiler mater A class. The current thermostat is a drayton manual one, and has 3 wires, i think live and neutral and call? Does anyone know how i switch this to a 2 wire thermostat (the honeywell cm907)? Thanks steve
  7. S

    Which way for economy?

    Hi Please can someone tell me which is the most economical & productive way of running a Boiler Mate A Class OV for my hot water. There is Constant and timed. If i leave it on constant, is it heating water all day even when unused or just on demand? Thanks steve
  8. S

    BoilerMate A-Class OV - wireless?

    Hi Guys Does anyone know of a good wireless programmer to add to this boiler? It has a built in manual 24 hour programmer, but the boilers on the 3rd floor...! id ideally like one that will allow me to boost for an hour, and allow 7 day programmes. There is currently a room stat, and...
  9. S

    Glowworn 45-60 - adding a room stat

    Does anyone know how to go about adding a room thermostat in a house with an old Glowworm 45-60 and a qe2 programmer. (Gravity fed!) Regards Steve
  10. S

    Gravity Fed, QE2 Controller and need wireless

    Hi I currently have a gravity fed system with a Grasslin QE2 Controller. Whats the easiest way to add a wireless room thermostat - wall mounted? Any help or guidance would be greatly appreciated! Thanks Steve