Search results

  1. P

    The New Micro Type Bayonet Cooker Hose !!!

    yes 10mm cu ,gas tap and various fittings.. phil
  2. P

    Corgi jobs

    Anyone can say they are competent......But the only way to prove it is by passing all the relevant gas courses..
  3. P

    The New Micro Type Bayonet Cooker Hose !!!

    Cooker hoses and hobs Do Not go together well. the oven underneath tends to damage the rubber and cause GAS LEAKS.
  4. P

    Thorn Apollo 50/65B Boiler

    most apollos have a overheat stat with connecting wires into the t/c wonder if that has been changed recently. and check the connections onto the t/couple are tight.
  5. P

    x200

    i have been using it for years on old spacesavers and bbu,s a good product. you may need to repeat every 2/3 years. phil
  6. P

    Baxi Solo 2 PF ( I think I need a new PCB,have you got one?)

    no checked pilot solenoid, it is a very rare fault but it turned out to be the main solenoid on the gas valve, had to change the complete valve.
  7. P

    Baxi Solo 2 PF ( I think I need a new PCB,have you got one?)

    and dont forget the old gas valve, which can some times send wrong information back to the board
Back