  1. dave1973

    Radiators getting hot when the DHW is used - Baxi Duetec

    Oh my god I've heard it all now . 8 years and your heating system is like mineral water ha ha ha. Must tell the lads at work this one!
  2. dave1973

    Radiators getting hot when the DHW is used - Baxi Duetec

    Most customers think a boiler service is more than enough. It's half a job and no most people don't want this done. Until I show the filthy pump that's cost a few quid to replace or the F and E tank full of crap. Then you will hear " you know what I can't remember when it was last drained, I...
  3. dave1973

    Radiators getting hot when the DHW is used - Baxi Duetec

    FiremanT , seriously drain your heating system once a year and add inhibitor. I'd say 50-60% of all breakdown I attend are due to dirty systems. Clogged pumps, heat exchangers, dirty sensors/thermisters and diverter valves!!etc etc
  4. dave1973

    Radiators getting hot when the DHW is used - Baxi Duetec

    Diverter valve, common and easy diagnose
  5. dave1973

    Radiators getting hot when the DHW is used - Baxi Duetec

    Your diverter valve is letting by. Basically when your hot water is called the central heating water heated and pumped from your heat exchanger should be diverted through your plate heat exchanger and make a circuit back around your boiler. If the diverter valve is letting by (not fully closed...
  6. dave1973

    potterton puma 80 and alpha cb25 faults

    Hello all, dont really use this forum much but would like to know if anyone could help. Firstly I manily do installation not fault finding hence my questions. Customer has called to say her puma 80 has hot water but no central heating. There are apparently no external programmer or room stat. I...
  7. dave1973

    new pump problem

    pump was the same 15-60 grundfos although the 15-50 there not too much difference same loads. Anyhow changed the air seperator and work spot now! could see anything wrong with the old one. The only thing I have changed was the feed pipe tight next to the outlet port on the seperater as to the...
  8. dave1973

    new pump problem

    cheers mick for info , still puzzled why one minute is was ok and a s soon a new pump exactly the same and set at the varies speeds its happend and it filled up no problems with no slow venting of rads!! :roll:
  9. dave1973

    new pump problem

    pump definetly fitted the right way and upstairs heating circut is working better than before although the rads down stairs are still slow to warm up and three are not working have checked all manual rad valves on them!
  10. dave1973

    new pump problem

    will remove air seperater tomorrow and replace with new, the over pump does slow down when set to 1. A bit puzzled why it could be blocked as it has been drained twice today can only think on last fill up sludge ect from f and e has blocked up feed port to air seperater. Any thoughts??thanks Dave
  11. dave1973

    new pump problem

    Hello all have replaced like for like a grundfos 15-60 pump as the old one was noisey and not pumping to full capacity, also half the down stairs rads where not working although upstairs if ok. Some partical blockage we think. The problem now is it over pumps through the f and e tanks and never...
  12. dave1973

    installer and bored want to to explore boiler fault diagnostics etc