    Putting smart switch after fused spur

    We have a heated towel rail with the electric supply coming via a fused spur switch in another room, as normal. I'd like to put a small smart switch between the fused spur and the towel rail, probably in it's own section of a dual surface pattress box, to better control the towel rail and to...
  2. J

    converting DSSO spur in loft to single socket plus unswitched FCU

    looking for some advice. I have a DSSO spur in the loft coming from the upstairs ring. This was installed for a future burglar alarm control panel. Got the alarm control panel now and looking to install, but it says an unswitched fused spur must be used...why this is I don't really understand...
  3. K

    FCU in Bathroom for Washing Machine

    Evening all, Renovating our bathroom from the timbers up, and it's electrical time. The house (a bungalow) consumer unit is about to be replaced with a modern unit and full suite of RCBOs. The bathroom wiring has the usual lighting circuit, but above the old mirror there used to be a 1 bar...
  4. M

    Cooker circuit in kitchen refit by cowboy kitchen fitter and electrician

    Hi, I would like to give thanks to every member of this forum, I have been watching and read upon many posts for the past few years and have learned a lot. I apologize in advance but I would very much like some advice on electrical work which has been completely messed up by a cowboy kitchen...
  5. C

    Extra socket in shed

    Hello Everyone, I simply want to add an extra twin socket in shed. The existing socket is I believe a fused spur, taken from kitchen. I have 2 simple questions: - Is the current set up (see pictures) ok? - can I extend directly from FCU or socket? thank you so much for your support and feedback.
  6. T

    Operating a shed light with a second FCU

    Greetings and apologies for my basic diagram, but hopefully it serves its explanatory purposes. Can I operate the shed lighting using a 3A switched FCU in this way? Also do the live and neutral of the load terminals simply connect to the two terminals of the light fitting, and can I use 1.5 sq...
  7. J

    Running a dual socket from single FCU?

    Hi all, I got a cable running into an airing cupboard in which I want to install a network switch and AC/DC adapter for a camera. The cable 2.5mm runs direct from consumer unit which is wired to a 16A fuse in the CU. Currently cable just terminates into a switch that I assume was used to power...
  8. B

    Trip Switch (internal) on a garden Chipper wont reset

    Even with the power disconnected. If you hold the trip switch in reset position, motor starts and runs perfectly until you release the trip switch (which is inside the switch panel, not accessible without dismanteling the switch unit). No signs of excessive heat, no bare wires, no burning...
  9. G

    FCU Feeding 2 Double Sockets - OK?

    Hi all, I had a similar thread a while ago but not wanting to necro-post it and also to try and ask a more specific question, I wanted to start a new one. So: I have a double socket in a hallway, with 2 cables going into it, so assuming that it's either part of a ring circuit, or the mid-point...
  10. cwhaley

    Outside Wall Lights - Patio Door

    A while ago I put a wall light up on the back of my house next to the back door. I believe I did this safely and this was my method: I took a spur from a nearby socket, chased the new 2.5mm T&E wire in the existing conduit (straight up from the socket), took this along the wall (at 100mm away...
  11. I

    13A FCU to single/double socket?

    Hi all, Just a quick one. I have an FCU which used to power a small electric fireplace however there is only one socket (wrong side of the room for necessary use) so need to either lug a big old extension cable around the perimeter or use the old FCU wiring and replace with a single or double...
  12. Bearman

    Kitchen - Cooker FCU + Grid Switch for Appliances

    I have been an active follower of advice on this site for some time and thought I'd take the jump and sign up. As a newbie, apologies if this question is duplicative, posted in the wrong place or if I've made any other faux pas. I'm currently learning the trade, but not anywhere near qualified...
  13. E

    Fcu problems

    Does anyone know why my fcu has supply and load as normal and an extra live for load and supply?? Ive had to re install my original fcu because I just can't get it wired properly. I have added a picture.
  14. N

    FCU off a single socket spur?

    Hi all. I've just installed a burglar alarm in the understairs cupboard. The manual calls for a 2A FCU to supply the power. Next to the panel, there's a single socket which appears to be a spur from another socket on the ring main as only one surface mounted cable goes into it. The single...
  15. L

    16 amp oven wiring

    Hello to you all and Merry Christmas first of all. I'm hoping the Christmas days after-celebrations boredom will provide me with some answers :D. Before I start I appreciate everyone will advise me to call an electrician and have it done by them. This is what I might do unless it's a very...
  16. O

    Can I spur a spur from a spur?

    Catchy title and it isn't as shoddy as it sounds- should read 'Can I spur an FCU from an FCU' but it wasn't nearly as catchy BCO has thrown me a wee curveball- he's just told me I need an extract fan in the utility room as part of other works (because the window was changed 2 years ago- why did...
  17. N

    Fcu with flex outlet at the top

    Anyone know where I might find one of these? I only see ones with flex outlet at the bottom or front. Or do I just stick one upside down?