MK Sentry 32A SP Type B MCB
Single pole one-module unit with a breaking capacity of 6kA. The switch can be locked in either the on or off position without affecting the ability of the trip mechanism to operate. Suitable for installation in MK Sentry consumer units. DIN Rail Mounted... |
£4.09 More Information |
|
MK Sentry 100A DP Switch Disconnector
Trip-free mechanism. Positive contact status indicator. Tunnel-type touchproof captive terminals with generous terminal capacity. AC-22A DIN Rail Mounted Fitting Trip-Free Mechanism Positive Contact Status Indicator Tunnel-Type Touchproof Captive Terminals... |
£12.49 More Information |
|
MK Sentry SP Type B RCBO
40A 30mA SP Type B Curve RCBO. Fitting Breaking Capacity RCD |
£20.96 More Information |
|
MK Sentry 40A 30mA SP Type B RCBO
18th Edition Amendment 2. Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted... |
£23.49 More Information |
|
MK Sentry 10A 30mA SP Type B RCBO
Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted Fitting 6kA Breaking Capacity... |
£23.49 More Information |
|
MK Sentry 20A 30mA SP Type B RCBO
18th Edition Amendment 2. Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted... |
£23.49 More Information |
|
MK Sentry 32A 30mA SP Type B RCBO
18th Edition Amendment 2. Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted... |
£23.49 More Information |
|
MK Sentry 16A 30mA SP Type B RCBO
18th Edition Amendment 2. Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted... |
£23.49 More Information |
|
MK Sentry 50A 30mA SP Type B RCBO
18th Edition Amendment 2. Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted... |
£23.49 More Information |
|
MK Sentry 6A 30mA SP Type B RCBO
18th Edition Amendment 2. Combination of a Type B curve MCB and a Type A RCD. Enables both overcurrent protection and earth fault current protection to be provided by single unit. Can detect and react to both AC and pulsating DC faults. DIN Rail Mounted... |