Wiring for ceiling lights in rooms under a thatched roof.
Intend to protect cables wih conduit. Therefor considering singles for ease of instal.
Each light will be supplied direct from a central control unit where relays responding to ELV wired switches ( and other controls ) will switch the 230 volt to the lamps
Is tri-rated single acceptable under BS7671 ? One electrician says it is and another says it must be double insulated singles. In which case 1mm twin and earth might as well be used..
ELV wired switches to allow small diameter cable causing minimum disturbance to the conservation protected walls of the grade II listed building.