Recent content by ajl

  1. A

    cellar drainage

    thanks lots. well if the electrical connections get wet i have other problems as the socket is 4 ft up the wall. the cellar is also a garage, ie only undeground on one side. as to the sump. i should of thought of that, i could have put it just inside the exterior door to the cellar, at least...
  2. A

    cellar drainage

    thanks for reply, good point about (fines). what i did in the end was . dig the hole, just over bucket size. then line the bottom with 2" waterproof concrete. then i sat a 300mm internal size concrete drain/culvert pipe in the hole, i figiured that this would probrably also be made of waterproof...
  3. A

    cellar drainage

    can anyone advise me? i am fitting a sump in my cellar ,i bought the house recently, there was a trench dug in the concrete floor to take water out. its been completely dry for 6 months and i am told it has been so since other houses have been built around me (the last 6/7 yrs). anyway i will...
  4. A

    where to start ,tiling..

    hi, i am about to tile my new bathroom. i have put a level line around the wall, about where i want to finish. i also have to go up the whole wall height where the shower will be. do i put the top tiles first and work my way down, cutting the last at the floor as req??? i have three fixed level...
  5. A

    shower

    ah, the toilet waste , hot water pipe and central heating pipes , feed and return,one of each.are in the duct , all pipes are covered with foam insulation and the duct is very big i could easily get another 10/15, 40 mm pvc pipes in there. presently the shower cable is cable tied to the outside...
  6. A

    shower

    ok, the cable is on its own.direct from the C.U. it is clipped thru the cellar ceiling up thru the first floor via the same boxed chanel the pipework uses. then it goes along the floor edge of the wall, up the wall that will form the shower back,tiled, and into the 8.5 kw@240v shower unit. the...
  7. A

    shower

    can someone advise me, can i run the 10mm2 cable up alongside the water pipe that feeds the shower unit? if i run the cable above the copper pipe and compression fitting ,then water should never be able to run up the cable and get into the conections???? otherwise what to do? also the cable is...
  8. A

    shower electics

    hah !! i am reading about the warming up of northern europe. and having had no oil for a few days i discovered that if you lay out your hose pipe, 100 mtre, it gets hot enough to have a decent shower, so if the trip keeps poping out i will run the garden hose into the bathroom, at least for the...
  9. A

    shower electics

    thats typical french, they figure that that as no one(they can concieve of ) would want a cold shower why pay to install cut off valves.. at this delicate stage i have not even asked EDF the difference in charge 30/50A supply, that would **** on my grand project. as i have been sweating my nuts...
  10. A

    shower electics

    i am sure the thing will drip, everything else has, fitted 90 degree valves for safety, just in case of my plumbing, and yes the only things that drip are the bloody olived valves, tighten more and off to brickolage to get new nut (split )... frankly so far french electrics, plumbing, at least...
  11. A

    shower electics

    yes the box coming into the house has 30a on it? if you need more there is a different tarif, apparently there is nothing else needed. what to do? the idea was to be able to avoid firing up the oil heating for good reasons..! however i am mindful that for the cost of instaling this shower...
  12. A

    shower electics

    ok thanks 10mm2 it is and 50a .. thats a bugger as i will have to notify EDF .thats french power to upgrade the supply.different monthly basic charge.. more.. thanks for all advise
  13. A

    shower electics

    ok i see replies. the shower is stated as 8.5 kw. the run will be 15 mtre it will be clipped to the cellar wall cieling for 8 mtre, run up a wall ,not plastered in for 4 mtre and the rest behind tiles in the bathroom. i dont know what the plaster is,thermal or not.. will a 36a trip be...
  14. A

    shower electics

    the guide suggests cable size for various lenghts of cable run. it does not refer,or i cant see it, to the size of the shower ie 7.5 8.5 9.5 10.5 kw. is this therefore not an issue? :?:
  15. A

    showers

    ok guys thanks, i have found a way to get 12 mtres of 4.5 mm2 cable to the shower point, will that do for 8.5 kw shower. no there is no storage tank, just mains press. there is a storage tank as part of the oil fired boiler. but thats not much help in this case. is the overhead isolator...