Recent content by crewy

  1. C

    fitting french doors to brickwork openings

    Hi all, Im in the process of building an extension and at the moment im up to dpc on the external wall and a block below dpc on the inside. Im thinking ahead and have decided i would like to install some off the shelf french doors 2090 high and 1190 wide. The problem is that this size dosent...
  2. C

    Damp Under House

    just buy or hire a dehumidifier, itll clear that up in 24hrs no probs
  3. C

    candy fridge probs

    I have a candy frost fee digital fridge freezer, its a built in version. The problem is the fridge section cant keep a constant temperature, i've set it for +5 but it wont get that low anymore. If its left alone it will eventually get to +6 but if you open it a couple of times it gets warm real...
  4. C

    main sewage pipe.help needed!!!

    Hi all, hope someone has a idea! I am planning an extension at the rear of my house and have come across a bit of a problem. There is a manhole cover in the way of the footings and i have to move it, the problem is that this is the manhole over a 6inch communal sewer and the pipe the whole width...
  5. C

    bathroom spot lights

    Hi all. I am hoping to instal 3 celling spot lights in my bathroom and just wanted to check i am doing this correctly. There is an existing celling rose and light switch, the new lights are 240v with 50 watt bulbs can i remove the celling rose and using a junction box connect the first light as...
  6. C

    testing for earth faults

    Hi, there is no light,bulb or holder. If i remove the red wire from the front controls it stops the gas on the oven comming through and the spark works and it doesnt blow the fuse on the oven control at all, if i use the grill it bows the fuse still.???????
  7. C

    testing for earth faults

    what?
  8. C

    testing for earth faults

    taylortwocities. I apologise but was unable to locate that post. Thanks for letting me know
  9. C

    testing for earth faults

    i have taken the case apart and have no 12-24 pin box, there is a spark generator,solenoid, 4 microswithes. change over thermostat,daristor what ever that is and oven door micro switch and clock with minute minder but no 12 0r 24 pin box.Any ideas???
  10. C

    Air Bubbles on a Plaster Skim

    Painting from the bucket is where your problem is, New plaster should always be sealed prior to painting you colour of choice. generally modern plaster is ready to paint when completely dry, around 5-7 days as you said but when more than 1 coat has been applied it could be longer. You said you...
  11. C

    testing for earth faults

    cheers sparky. ill post the pics 2mor
  12. C

    testing for earth faults

    there is a diagram, should i take some pictures to show you. Would you have time to take a look. Thanks
  13. C

    testing for earth faults

    Yep there is a clock which works fine, The problem is when i try to switch the oven or grill on it blows the fuse. it has worked fine for years untill now. I have tested the socket to which i plug it into and there is 240v there, i pluged in the cooker and tested the flex connections and there...
  14. C

    testing for earth faults

    I have a problem with a gas cooker. The fuse in the plug keeps blowing. I have tested all that i can and was wondering how i would go about testing earth faults on this cooker and other electrical items in general. Thanks
  15. C

    testing for earth faults

    Hy all, how do i test for earth faults. I have a very good quality tester which will test volts amps and continuity. Thanks for your help
Back