Recent content by Farmacist

  1. F

    Freesat

    I currently have free view to my plasma tv. The tv has a built in free sat decoder. I want to fit a free sat dish and cable to the tv. But there is only 1 lenght of coax in the wall. Is it possible to use this one lenght from the loft to to TV (about 2m), and then split the signal before the TV...
  2. F

    Drilling two scary holes today - any tips?

    There a 5 methods of conecting to the HWT in the stuart turner fitting instructions, only 1 of them requires putting a hole in the tank. I am not saying it wrong, just not needed, especialy if you are worried about doing it (drilling the whole). 50g tank is fine, you will run out of hot water...
  3. F

    Shower pump that can pull the water?? anyone

    contact either stuart turner or salamanda tech help line and they will advise you which pump you need. Some have pressure vessels attached, which may be what you need. I think that all pumps push and pull, cos they course a pressure differential, any way that is not that relevent, what may...
  4. F

    Drilling two scary holes today - any tips?

    there should be no need to fit any flange to the HWT, just tee off the hot water outlet and fetch the pipe stright down to the pump. For info look at stuart turner or salamanda web sites. I have a 3.5 bar ST pump like this and it gets all the hot water it needs.
Back