Recent content by fisher47

  1. F

    water in washer draw ? ? ? ?

    hi, if you mean that the comfort section is blocked. then remove the cover off that section you may have to take out drawer there is usualy a push down release device in drawer. the cover will have a tube sticking down under neat it, clean all round and IN tube also the same on other part of...
  2. F

    indesit dishwasher- not draining

    hi, if you select a new programmes the first funtion the machine will do is empty if you hear no sound or a faint hum its likely a blocked pump eg fishbone piece of glass etc.frank
  3. F

    indesit dishwasher- not draining

    hi, most dishwashers have a set time to fill eg. 4 mins. if it dos not fill within the set time main board thinks there is a fault and flashes at you......supply line is not restricted , mesh filters at end of fill hose are not clogged and tap is fully opened. hose kinked when macine is pushed...
  4. F

    Washing Machine Worries...

    put your money towards a new one. chances are there will be more damaged to main board from feedback from wet motor and pump . frank
  5. F

    AEG Favorit 60870 Dishwasher

    code will remain there till you solve your leak problem.there is a float on the base of machine nearest the floor that lifts switch when water leaks on to it.the base can be removed by turning machine on side NOT upsidedown. place large towle on floor. pin pointing leak can be the hardest bit...
  6. F

    aeg favorit 86070 vi

    hi aldi, rince aid is dispence by the use of a small solinoide which can not be bought seperately you have to buy whole unit appox 80 euros it may be faulty or may not be getting message to operate from main mother board. other option is to use 3 in one tabs with built in rince aid.frank
  7. F

    hi all i am a domestic appliance service engineer, if i can help give me a shout. frank

    hi all i am a domestic appliance service engineer, if i can help give me a shout. frank
  8. F

    hermann boiler lockout

    hi have hermann 24se boiler in lockout state. green and red lights on but not flashing.not reseting when dial turned to reset position. water pressure good all taps on and gas suppy on. thanks. frank
Back