Hi Sparkymarka. I can confirm I have disconnected the wires in the panic terminals of the keypad replacing them with a small jumper wire and exited engineers mode and now all faults have cleared. I have also now reconnected panic terminals and we are able to set and unset the alarm again...
Ok so removed cover of downstairs keypad and the is a green and white wired into panic. All looks good and secure, refitted keypad faceplate ensuring tamper switch made contact and clicked. Checked inside panel again all wires secure and in place, refitted panel lid ensuring tamper switch made...
OK so can now scroll through circuits using "A" (up) and "C" (down). After reading info I assume I have 11 circuits in use all 11 show resistance information
1. Panel FE 2K1
2. Panel ER 2K1
3. Panel NA 2K1
4. Panel NA 2K1
5. Panel NA 2K1
6. Panel ER 2K1
7. Panel NA 2K1
8. Panel...
Thanks for checking it out on another panel but when I press 199 tick it displays circuit 1 and resistance value as you say but when I press 3 it adds a 3 to top line
Thanks Sparkymarka for your reply. I have checked and checked again that the tamper switch is closing when lid shut and that there is nothing is disconnected in the panel. I don't have a panic button. I thought that if the tamper showed as inactive that it could be cleared only active would mean...
Hi All
I have a scantronic 9751 alarm panel that alerted low battery the other night. Very persistant it was :-(). I changed battery and it required an engineer reset. It is a new house for me so didn't know code so i carried out the 1st stage reset so have now default codes. However I still...