Recent content by Jimph1

  1. J

    tongue and groove flooboards over joists

    hi im just About to re lay new tongue and groove flooboards over the joists in my bathroom. I have everything to hand except floor clamps. Do I need to use floor clamps when Laying tongue and groove boards ?. Thanks Jim
  2. J

    baxi eco 80 central heating temprature control

    Thanks for reply tony, I hope it's not the Pcb board , shall I try replacing the following sensor first - and do I need to smear this sensor with silicone heat sink compound ...
  3. J

    baxi eco 80 central heating temprature control

    Hi guys my baxi eco 80 combi boiler central heating is very hot even though the temprature dial is set low on the front panal of the boiler, I dont seem to have any control over the central heating temprature at all when switched on ? Any ideas what the possible cause is ?
  4. J

    Baxi Eco 80 set at 1.5 but going up to 3 Barr ?

    The only plumbing that has been done is all the radiators have been replaced . No plumbing done at boiler, just drained boiler and system and refilled with inhibitor. I will order the plate heat exchanger and get it fitted. Thanks
  5. J

    Baxi Eco 80 set at 1.5 but going up to 3 Barr ?

    Filling loop is disconnected so I'm looking at a new plate heat exchanger ? Before I buy one theres nothing else it could be? Also im assuming its quite a quick straight forward job fiting plate heat exvhanger to the baxi eco80 ? If any one has fitted one can you give any info. Im quite hands...
  6. J

    Baxi Eco 80 set at 1.5 but going up to 3 Barr ?

    Hi there folks. I have a baxi combi eco80 boiler and the pressure is rising away up to 3 barr (within a few hours) and staying there even after I've drained the boiler , put in sentinel inhibitor, re filled to 1.5 Barr , bled all radiators,and disconnected filling loop. Anyone any idea how...