Recent content by joemac666

  1. J

    worcester 24iJunior help needed please

    lol, duh.............Just to keep the record straight WB (lol), replied to me with the excuse that they dont sell the fan because they found that they were being damaged in transit..........the fan pcb gets damaged however the control pcb is fine, I advised a solution....pack them the same way...
  2. J

    worcester 24iJunior help needed please

    Thanks Peedee, I have already done that and contacted them yesterday. Both ebmpapst and their dealers wont sell it to me and just refer me back to worcester..........oem part cant sell it they say.
  3. J

    worcester 24iJunior help needed please

    Thanks Peadee, the board is made by ebmpapst with serial number 0572L11-08, also AM 051005. The fan is worcester part number 87172044530 and the ebmpapst number is RG128/1300. I just think its a shame to replace the whole fan.... and dearer Thanks for the replies guys except....... In...
  4. J

    worcester 24iJunior help needed please

    Hi Guys There seems to be a bit of confusion, its the fan that the problem is with not the pump. The flow and return does not need isolated. I was talking about the pipes outside of the boiler, I had not even taken the cover off at this stage as it should not have required it. The...
  5. J

    worcester 24iJunior help needed please

    Hi Guys I replaced the flow and return to the boiler from my house to the garage. I drained the system, hooked up the new pipes, filled the system up to 1.5 bar, vented the rads and switched the thing on. The boiler did not work and suddenly stopped. I took the control panel off and a fuse...
Back