Recent content by kazclan

  1. K

    vokera compact 28 lockout

    hi thanks for advice but i got the boiler thru a contracting firm i work close with, and they kept the receipt for vat purposes. they now cant be bothered to trace it. i have engineer coming today from vokera @£175. sometime between 8.30am and 5.00pm. i wll post his findings if anyone is...
  2. K

    vokera compact 28 lockout

    hi could anyone please help me? i have a vokera compact 28 about 18months old. last few weeks it has been locking out when heating and hot water were on together. watching it, it was locking out after it was trying to ignite after it had gone out on thermostat. but now it also goes out on hot...
  3. K

    vokera compact 28

    hi seems to be when heating and hot water is on. stays on for about an hour, then locks out. i then reset with the dial on front of boiler. it strikes up ok then it goes out again. every now and then it wont ignite after reset, and i keep reseting till it does ignite. thanks for your...
  4. K

    vokera compact 28

    hi my vokera fires up ok, but after a while just locks out for no apparrent reason. pressure sits at around 2 bar. turned all thermostats to max. is there is anything i can try to solve the problem? any help would be gratefully recieved thanks mark
  5. K

    diplomat cooker

    if i had to replace stat. which one and where would i find it?? many thanks Mark
  6. K

    diplomat cooker

    hi. i have a 5 ring twin oven diplomat cooker purchased about 2 year ago. the problem with it is, the cooling fan does never turn off any more even when cooker is cold. Any help would be gratefully received. thank you in advance Mark
  7. K

    vokera 24 hw problem

    thanks for getting back to me. looked thru manual. there are 3 thermistors shown. which one would be the one i would need to change? took out restrictor soon after boiler was fitted after advice from this forum. many thanks mark(kazclan)
  8. K

    vokera 24 hw problem

    hi there could anyone help me with boiler problem? i have a vokera compact 24 combi boiler. when i turn hot water tap on, boiler kicks in for a few secs then goes out again. this continues for the period of time the tap is turned on. hence the water goes warm the cold but never gets a chance...
  9. K

    electric ceiling heating

    hi pepene i fit a lot of ceiling heating in new build medium secure buildings. in my experience the thermostats have to be turned up to maxium to try and draw the heat down in the rooms. for an average size room you need about 1kw of ceiling heating, less on smaller rooms. if you muliply that...
  10. K

    vokera compact 28

    took out restrictor on inlet. rubber o ring seemed to have seeled against restrictor. removed o ring, fell apart in my hands. pressure is now better than i could of wished. thanks for all your help and of course the money you saved me.
  11. K

    vokera compact 28

    could you recommend a scale inhibitor, type/make. i believe it is quite a hard water area in the part of cheshire i am in. cheers
  12. K

    vokera compact 28

    thanks for your time and advice
  13. K

    vokera compact 28

    so its worth cleaning restrictor and if that fails replace heat exchanger??
  14. K

    vokera compact 28

    have not taken out restrictor yet. wanted advice first from people who know what there talking about. dont mind changing exchanger if thats what it definetly is
  15. K

    vokera compact 28

    flow has dropped to about 1 litre a min. what about restrictor or boiler flush
Back