  1. K

    will i need a bigger combi boiler

    Got to admit I have 2 combi's & gas hob running off a u6 meter, one combi for the house & one for a 4000gallon koi pond, works perfectly, even when they are all on at the same time :shock:
  2. K

    all in one WC

    Anyone seen or fitted/used one of these, what do you think? http://cgi.ebay.co.uk/Macerator-toilet-All-in-one-Saniflo-style_W0QQitemZ280127308812QQihZ018QQcategoryZ71284QQssPageNameZWDVWQQrdZ1QQcmdZViewItem
  3. K

    Biasi heating a koi tank

    Got a Bargain with the boiler, brand new £150 on ebay so could not say no :lol: Ideal for the pond, jump leads incase it needs a kick start being Baxi :oops:
  4. K

    Biasi heating a koi tank

    Forgot to say it is also 7ft deep
  5. K

    Biasi heating a koi tank

    Those koi are around 26" - 30" long lol, pond is around 4200 gallon, Heat exchanger is 100,000 btu & boiler is 50,000 btu, also has a rad run off it. The boiler can raise the temp of the pond by 1c in about 30 mins john
  6. K

    Biasi heating a koi tank

    When the pond is heated the koi are active & fed all year round
  7. K

    Biasi heating a koi tank

    You will also need a heat exchanger & Digistat to control the pond temp, if is a combi for the house heating & the pond it will need a couple of zone valves on it. you will be surprised how inexpensive it can be to heat if you stick to the ambient temp, the idea to heat a koi pond is to stop the...
  8. K

    Half pedestal problem

    The 2 strange washers with 1 large hole and 3 small holes, are hung onto the rawl bolts that fasten the Hand Basin to the wall. The springs clip into one of the smaller holes & are left hanging, when the half pedestal is offered up to the basin pull the springs & clip them into the holes in...
  9. K

    New syphon but the loo still won't flush

    Stupid question, but is the water level high enough in the cistern ??
  10. K

    Corgi Renewal

    Hi, What date is the Corgi renewal due, beginning or end of march? Thanks, john
  11. K

    Pub Argument - Boiler Connections

    Hi, The flow pipe always leaves the boiler & the return (returns) to the boiler john
  12. K

    No Hot Water

    There will be a large screw on top of the pump, unscrew it, dont worry, there will only be a small amount of water coming out & hopefully air, if you are feeling confident you can undo the nuts (22mm) either side of the pump (one at a time & not fully off the valve), this will release the air...
  13. K

    No Hot Water

    HI, Does the Boiler fire up on hot water only ?, the way you say it is piped up sounds like there could be an air lock, maybe behind the pump, have you tried bleeding the pump? john
  14. K

    Baxi Duotec combi

    HI, JUst been to price a job & the guy wants a Baxi Duotec combi 28, anyone fitted one of these, any good etc john
  15. K

    signing off

    HI, Can I sign off a central heating system with corgi if I only wire it with a temp lead to commision it ( dont have part P) until the electrictian wires it ?? The house is getting a rewire & the guy wants his electrician to do it john