  1. L

    co recording

    hello, imjust wondering if you comeacross a boiler for a landlords check and cant do a co test ie boiler hasnt got test point, flue outlet not accessiable ie height or neigbouring property. i simply write unable to test co test recommend co alarm??? ta
  2. L

    pat testing

    hello, could someone clarify . is a full electrical test on rental properties a legal requirement before renting like gas and epc? what about pat testing? is that also compulsory? is there a demand for this? 3 jobs a week would do me to complement my gas and plumbing jobs .thanks
  3. L

    going it alone

    hello, could someone clarify . is a full electrical test on rental properties a legal requirement before renting like gas and epc? what about pat testing? is that also compulsory? thanks
  4. L

    going it alone

    really. i though bit of advertising, cheaper price give it a year for repeat business. you really think its the holy grail? fires that never have been checked ,bbu never been checked. i know the private sector is hard. under no illusiions about that. just doesnt seem that hard to do. 4 a day...
  5. L

    going it alone

    would like some views pls. moving to west midlands. thinking of setting up on my own . just doing landlord certs 60 quid a pop 4 a day. how possible is this?big area with plenty of business, landlords agents etc.
  6. L

    chimney sweep mode

    so if its working on service mode but not on central mode as per normal then this confirms that roomstat/timer are the cause??
  7. L

    chimney sweep mode

    yep.german boilers have chimney sweep mode as service mode
  8. L

    chimney sweep mode

    hi. if a boiler wont fire up for central heating demand but fires up chimney sweep mode doesnt that quickly tell you that its the external controls ie roomstat, timer thats the cause since the boiler firede up for chimney mode it must be ok. talking about worcester greenstars, valliants. thanks
  9. L

    scaled exhangers

    great stuff.thanks
  10. L

    gas drops

    cheers. ive been using 2mb as max drop too myself and was told off for capping of appilances at 6mb drop e6 meter by my boss who was a corgi inspector!!!!!!!thanks
  11. L

    scaled exhangers

    hi. is there anyway conclusively to tell that a scaled HE is the cause behind DHW poor temprature?? some one has mentioned getting a digital thermometer and doing a thermal survey on the exchanger? but surley a scaled/ defective thermistor would also be the cause of poor dhw temp.any ideas as...
  12. L

    gas drops

    hello. can anyone explain why a 4mb gas drop and even 8 mb gas drop on e6 meters are acceptable. surely an 8 mb drop with a cooker connected cant be good!!!!!is there anyone out there who has a zero drops policy?? thanks
  13. L

    gas valve modualation

    hi. ive re3cently passed my ccn cen1 so fairly new to the industry. just a question regarding modulation. have i got this right--- gas valve modualtes in this order of sequence ntc (working ok)transmits corrosponding voltages via pcb to gas galve to modulate to the required demand? if...