  1. N

    New bathroom upstairs

    I've converted my 3 bed end terrace to have an upstairs bathroom. I've had it valued since and it's gone up in value slightly above the rise in house prices in my area. Get a fe estate agents in and see what they say.
  2. N

    Mobile down cavity

    It would be quite funny to leave it and phone it a few days later to drive soemone else mad!
  3. N

    New Alarm System

    I had noticed it had gone slightly off topic lol.
  4. N

    New Alarm System

    Well guess what, two 12 hour days later and it's fitted and fully working. :D Used D-EOL and i'll do so in my future homes. Few teething problems at the end. Most time consuming thing was lifting floor boards and running wires. Main problems were: 1. Tamper light showing on remote...
  5. N

    New Alarm System

    I shall keep you informed. Think i'll be hanging around this forum more in future, seem to be some decent knowledgable people on here. Thanks again. (a thumbs up icon is needed!!) :D
  6. N

    New Alarm System

    RF Lighting, Security Warehouse and spark123 thank your for your inputs. Its greatly appreciated! I'm competent at soldering, but Spark's method sounds a lot easier, I can't see any reason not to go with EOL. I know exactly what I'm doing now and fitting the alarm tommorrow. I think...
  7. N

    New Alarm System

    Thanks Saxondale, So I'd reduce the 33K resistor to 20K and add a 10K. Where would the 10K be positioned on my diagram? Just checked the diagram from the manual that RF posted, Does the 10K go inline between the Zone on the control panel and the alarm tab on the PIR? I take it you solder the...
  8. N

    New Alarm System

    Thanks RF lighting, your post makes sense. Joe, the main reason I wanted to go with EOL, is because hopefully if there is a fault it'll be easier to locate.
  9. N

    New Alarm System

    Lol, answering my own questions, just phoned texecom and the AMQD isn't compatible with the veritas excel. Can someone confirm that when using EOL I don't use Global tamper. Also is this the correct way to wire a Prestige QD PIR with EOL: Is this the correct wa to wire a contact...
  10. N

    New Alarm System

    Actually I've just read on here that Texecom Prestige AMQD PIR won't work with my Veritas Excel. Is that true?
  11. N

    New Alarm System

    Ok I think I have got my head around this so when using EOL I don't use the Global Tamper circuit. EOL shall show up with which individual item was tampered with. Global Tamper shall just show that the system as a whole was tampered with.
  12. N

    New Alarm System

    Ok, the installation instructions are confusing me slightly. I think I can either wire the PIR/Contacts in either global tamper OR EOL. Is this right? If yes, then which is better? I'll only have one item on each zone if that makes any difference?
  13. N

    New Alarm System

    Thanks for the reply. I've ordered the texecom one yesterday and its arrived today. :-) I don't think I need the extension as the alarm panel shall be mounted under the stairs with the remote panel at the bottom of the stairs, so I'll hopefully hear it anyway. I'll keep the fire and...
  14. N

    New Alarm System

    Anyone?
  15. N

    New Alarm System

    After being broken into the weekend before christmas I've decided to fit an alarm(I know its a bit late). From reading this forum for the last week or so I've found two kits that seem to fit what I require. Which is: Alarm with remote keypad speech dialler 2 door contacts 3 Pir's 1...