Recent content by pauloc

  1. P

    gas fires

    in london they do. waste of loads of money because it looks nice!!!! i suppose elderly with radiant fires in social housing are more prone to using fires.
  2. P

    gas fires

    i was hoping a few of you could share some thoughts on fires.looking at the hse reports on co incidents over past 14 years.im surprised out little gas fires feature. 1 fatality in 2008!! i at risk so many dfe fires that have no vents. as we know fires are a favourite of illegal workers. wack it...
  3. P

    ventilation

    120cm2 in size.
  4. P

    ventilation

    hi. im wondering are your thoughts on dfe ventilation that goes via floor? went to one recently. sofa over the vent. explained to customer and ncs it. but im thimnking i should ar these. and tell customer to relocate vent just to cover myself
  5. P

    customer moron!!help

    thanks. ive never had a complaint thats all. and arguing over a few quid is not worth the hassle. hes a doctor and just moved out. i dont think he pulling a fast one. i genuiely think its one of those unfortunate coincidences that i turn up and its gets stuck on heating. hes not a boiler man so...
  6. P

    customer moron!!help

    ive never had a prob too be honest. done hundreds with no payment issues. most of mine are first time , young professionals moving out. estate agents i dont work for, nor chaps with loads of flats.
  7. P

    customer moron!!help

    hi guys. ive recently gone self employed and would appreciate some advice. went to do a landlords gas check. took cover off boiler had a peak in combustion chamber, check case seal, gave quick hoover as was wee bit dirty. did usual landlord gas checks on dhw mode only. day later he phone me...
  8. P

    delayed start suprima

    hi. ive noticed with suprimas, profiles primas that amny of them take an forever to spark up. is this a sign that the pcb is gradually failing.?many thanks
  9. P

    pump

    could anyone tell me if there is a type of allen key that goes over the fitting as aposed to the normal key which simply slots into the fitting?
  10. P

    pump

    thanks gas for you. regarding water coming out of vent shaft. i assume there shouldnt be a flow of water coming out no matter how small.??was a bit worried when i took out vent plug as was expecting a river but it was a small constant flow which doesnt look right to me. yes voltage was 240 and...
  11. P

    pump

    went to worcester 28 rsf. louyd noise from pump and overheat kept being activated. resistance and voltage to pump ok. took out vent plug and constant dribble flow of water from shaft. also shaft not rotating when boiler on. new pump? new to fault finding so want to be sure before order pump on...
  12. P

    y plan

    hel;lo. y plan . can get heating only when hot water and heating selected on programmer. faulty diverter. would it be swollen rubber ball or motor? ta
  13. P

    high pressure

    hello guys . went around to boiler. worcester combi 25 cdi greenstar. noticed pressure was at 2.5 bar. assuming installer had overcharged it went to let some water out of rad and all that came out was air, lots of it. anyway i then noticed the gauge dropped down to 1 bar. just want to know can...
  14. P

    y plan switch live

    hello. if there is hot water demand on a y plan the boiler switch live wont be live as the boiler is operated by cylinder stat directly. switch live will omnly be live in central heating demand. am i correct? many thanks
  15. P

    b.p.

    MORNING. curious. would like some enlightment on something. wondering how can a baxi solo have burner press at 16 mb despite only 14kw rating yet a puma have the same b.p. yet does 30kw . bit confused about that one. ta
Back
Top