Recent content by pw21

  1. P

    replacing switchmaster programmer

    Hi, Please can anyone advise if its possible to replace a Switchmaster 400 programmer for a more modern digital type controller. The system is a y plan, with a drayton ma1 three way valve. The wiring diagram i have for a y plan system shows a hot water off wire coming from the programmer...
  2. P

    worcester bosch 24i combi

    Thanks for the replies. It's sort of fixed at the moment - the overheat button had popped out. Pressed it back and everything is working again. It's worked fine up til now so not sure why it would cause the overheat button to pop out
  3. P

    worcester bosch 24i combi

    Hello, I really hope someone is able to help with the following. The boiler is a Worcester Bosch 24i combi, it's not lighting for central heating and its not lighting for hot water (ie when a hot tap is opened). It has a permanent orange light on. the pressure gauge reads just under 1...
  4. P

    Ideal Response 120 - big bang and fan full of water

    Why get a megaflow and use with a combi boiler ?
  5. P

    boiler ignition problem

    Hi there, We have a problem with a Glow worm economy plus boiler (about 11 yrs old) When turned on it makes a clicking sound for at least 6 minutes before lighting. Gas registered plumber has changed the gas valve, the pcb and has renewed one of the parts on the fan but it still takes about 6...
  6. P

    Programmable thermostat

    Hi all, Is it possible to change a Potterton PRT2 room thermostat to a Honeywell CM907 seven day programmable one? And is it easy to do? Thanks in advance
  7. P

    banging 3 way valve

    when heating is selected it's just one single bang. - thanks
  8. P

    banging 3 way valve

    The system is open vented with an f&e tank in attic, But when ever the central heating is turned on there is a loud bang (or knock) from the 3 way valve in the airing cupboard. But no noise at all when just hot water is selected. Any advice gratefully accepted. pete
  9. P

    leaky shower cabin

    Has anyone fitted one of the shower cabins from Wickes ? Fitted one a couple of weeks ago but after sealing everywhere I can think of with silicon, water still gets through the screen and catches on the front of the tray behind the tray lip. thanks
  10. P

    scaled up Unvented cylinder

    combi valve is fine, there is a cold water take off just after the combi valve and flow & pressure is fine on all cold outlets. - Hot outlets are a different story though! I like the sound of the Aquavac
  11. P

    scaled up Unvented cylinder

    Does anyone know a way of removing scale from the bottom of a Santon Premiere Plus 210 litre direct cylinder (2 x immersions)? I believe the bottom is so full of scale that it's restricting the end of the pipe supplying the cold water to inside the cylinder. I thought I'd remove the...
  12. P

    strange sounds from Ideal Icos

    Thanks for the reply Gasforyou, while checking the condensate for blockages I noticed it was dripping constanty, even though the boiler had been turned off for 48 hours. Decided to phone Ideal who said it sounded like heat exchanger needs replacing. They said they can repair it for £210...
  13. P

    megaflo reset bottom switch now smelling

    It does sound like you need someone to look at it. If you can smell burning then keep it all turned off and wait for the engineer. With a bit of luck it won't be a too expensive repair. regards pete
  14. P

    Anyone recognize this rad valve?

    I agree with Heatingman. Houses on an estate near me have these valves, one pipe systems and when valve is shut flow still goes through valve body but not into the rad. rgds
  15. P

    strange sounds from Ideal Icos

    Hi there, The boiler is an Ideal Icos HE18 (approx 2 yrs old) and has an f&e tank in the loft. The flow and return pipes go from the boiler on the ground floor, up to the loft, then across the house and back down to the airing cupboard. The problem is that about 15 mins after being turned...