  1. S

    brown stians in plaster

    help please!! we have had a new damp course cream injected into our property walls and the internal walls were stripped bear of plaster up to approx 12000mm because of previous damage to the plaster from damp. our plasterer scratch coated and rendered then finished plaster the walls upto the...
  2. S

    failed electric certificate for rented property

    thank's guys!!! i have not been given the certificate yet,only got the call today. i will get back when i have the results.he did say if was probably mice damage in the loft. i will put it too him regarding the test to isolate!! thank you
  3. S

    failed electric certificate for rented property

    No!! not prepared to rent in this condition. seeking advice on the most cost effective way to repair !! will it need re wiring or is there a way to pin point area of damage? thakn you
  4. S

    failed electric certificate for rented property

    i have just had a full electrical test done to a property we are about to let. the electrician informs me that the lighting circuit has been failed on the account that he thinks there is mouse damage somewhere . he also informs me that the only way around rectifying the problem is to do a full...
  5. S

    Separate Taps and spout - help...

    in fact reading your question again ,spout beeing a distant from valves. I would come out of valves in 22mm and reduce down to 1/2 just before the spout with a 22mm to 15mm reducer and connect to the spout with a 1/2 compression tap connector.
  6. S

    Separate Taps and spout - help...

    mi = Male iron to copper. i would use male iron to copper compression and then reduce down on the out coming flow to 15mm with insert compression reducers.
  7. S

    baxi 105 e doesnt work can you help me

    no smell!!just a loud noise coming from the pc board area. should there be power through to the fan if the pc board was ok?or does the power come via the pc board for the flue fan? what is the approx cost for a pc board? and for a new fan? does any one know good place to get one at good...
  8. S

    baxi 105 e doesnt work can you help me

    could i carry out the test myself or would this be a corgi guy/service engineer?
  9. S

    baxi 105 e doesnt work can you help me

    i have a baxi combi 105 e stopped working and fault light is changing from fan fault to ignition fault etc .it does run the pump when i re set but the pc board makes a loud clicking noise for approx 25 seconds then boiler returns to fault lights lit. i have checked with an electrician...